ceiling will in most cases require a forced air flow by means of a ventilator to prevent
overheating.
5.4.5 Mounting on horizontal surfaces
When the radiator has to be positioned a horizontal surface (e.g. on top of an interpreter
booth), the distance between the radiator and the surface must be at least 4 cm (1.5 inch) to
enable enough air flow around the radiator. This can be achieved by using the suspension
bracket as a support. If this is not possible, switch the radiator to half power. If the radiator is
used at full power on top of an interpreter booth, the ambient temperature must not exceed
35° C.
5.5 Low Power Wide Beam Radiator
Radiators in permanent installations can be fixed to a wall, hung under a ceiling or balcony or
secured to any sturdy material using the unit's built-in bracket and mounting adaptor supplied
with the radiator (Figure 5.15). In non-permanent installations, a floor stand can be used. The
mounting adaptor enables the radiator to be positioned for optimum performance.
Figure 5.15 LBB 3410/05 Radiator Mounting
5.6 Integrus Charging Units
Wall mounting the charging cabinet
LBB 4560/50 is suitable for either table-top or wall-mounted use.
It can be wall-mounted using 5 mm (0.19 inch) screws, with a head diameter of 9 mm (0.35
inch). The screws and plugs delivered with the LBB 4560/50 are designed to mount the unit
on a solid brick or concrete wall. Two holes, 8 mm in diameter and 55 mm in depth, must be
drilled 500 mm apart (see Figure 5.16).
WARNING!
To comply with UL and CSA regulations, the charging cabinets must be mounted in such a way
that they can be easily removed by hand in case of emergency.