FLIR
26-4 Camera Handler Release Notes
Setup
D-Series D-Series camera returns incorrect firmware version number in the
IRDeviceVersionGet CGI response. Camera firmware version number is only
available on the main page of the camera’s web configuration tool. The camera
firmware version number displayed on NVR is incorrect.
F-Series Video image streamed from a F-Series camera always has a big border when being
displayed on NVR and Victor Client.
F-Series
D-Series
PT-Series
Video image of moving objects looks interlaced on Quick Time and Java Applet Web
Browser. The interlacing may only have minimal effect on the Victor Client with no
noticeable effect to the Victor Client image. The interlacing will noticeably affect the
Image displayed on the NVR Live View and Java Applet on the Alarms page.
Step Setting up a new camera
1 Models: PT-Series/D-Series/F-Series
Reset the camera to manufacturing default
Open Camera Web Browser
Select Configuration File
Go to Factory Backup & Recovery Window
Select Restore to restore camera to “factory defaults”
2 Models: PT-Series/D-Series/F-Series
Adding CGI Interface
The FLIR camera’s CGI Interface must be enabled through Camera Web
Configuration Tool. This step must be performed before setting up a FLIR
camera’s IP address on NVR.
Steps for enabling the "Nexus CGI Interface"
Open Camera Web Browser:
Select “communications”
Select “Network Remote /VMS”
On Interface Configuration Page Select “Nexus CGI Interface”.
Select “Add”
Click Create.
Click Save.
Stop Server
Start Server.
Note on port number for Nexus Interface:
Port 8080 is the designated port for communication between NVR and
FLIR camera server (Nexus Server).