Bosch D9112B User's Guide Page 35

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 34
WALK TEST ?
Walk Test
Description
Use this function to test command centers, detection devices,
and sounders (both interior and exterior) to be certain they
function properly. You can review untested points at your
command center to help pin-point any problems.
You cannot arm your system while in the walk test mode, and no
alarm reports are sent to your security company unless a 24-
hour point is activated (such as fire or panic).
Upon initiation, the walk test will test the burglary bell pattern
on the bell output and ring the command center burglary bell
for 2 seconds. The AC will be disabled for 4 minutes in order to
test the system’s battery power. If the battery cannot maintain
the system for the 4 minute period, the command center will
appear to go dead. If this happens, contact your security company.
At the end of the 4 minute period, AC is returned to the system
and the panel restores. To test individual detection devices, simply
activate sensors and open protected doors and windows one-at-
a-time. As each detection device is faulted, the Command Center
emits a brief tone and the display indicates for 60 seconds that
the point has been tested. This verifies that each detection device
is working properly.
Using Walk Test:
1. Ensure your command center shows idle disarmed text.
2. Press the COMMAND bar. The display shows SYSTEM
COMMAND.
3. Press the 4 key, followed by the 4 key.
Note: If you prefer, you may use the Command Menu in place
of steps 2 and 3 to initiate this function. Press the MENU
key to enter the Command Menu, then press NEXT
repeatedly until you reach the WALK TEST ? prompt.
Press ENT.