3939
Option 2: Vertical balanced fl ue system maximum height
Components
Part No. 125mm
7 716 190 103 7 716 190 033
Maximum lengths (mm) & no. of components required
Greenstar Heatslave II series
125mm 8,000 1 up to 7
Option 1: Vertical balanced fl ue system minimum height
Components
Part No. 125mm
7 716 190 103
Minimum lengths (mm) & no. of components required
Greenstar Heatslave II series
125mm 1,080 1
Option 3: Vertical balanced fl ue system with two 90º bends
Components
Part No. 125mm
7 716 190 103 7 716 190 033 7 716 190 034
Maximum lengths (mm) & no. of components required
Greenstar Heatslave II series
125mm 6,000 1 up to 5 2
Option 4: Vertical balanced fl ue system side discharge
Components
Part No. 125mm
7 716 190 103 7 716 190 033 7 716 190 034
Maximum lengths (mm) & no. of components required
Greenstar Heatslave II series
125mm 6,000 1 up to 5 2
Vertical fl ue options 1-4 illustrate common fl ue installations. Other confi gurations of the fl ue system are possible up to,
and not exceeding, the stated maximum fl ue lengths.
Note: The maximum fl ue length must be reduced by
the following amounts for each additional bend used.
A fl ue damper is required for effective fl ue lengths
greater than 6m.
45º bend 90º bend
80/125mm fl ues
500mm 1,000mm