Operation
The Greenstar Heatslave II is supplied as standard suitable
for sealed primary water systems. The appliance contains
an expansion vessel, 3bar pressure relief valve, pressure
gauge and an automatic air vent.
Oil
These appliances are for use on 28 sec kerosene fuel only.
Hot water mode
With the appliance in a standby condition, i.e. the heatbank
at a temperature set by the hot water thermostat, when a
demand for hot water is required the flow switch will
energise the pump and circulate primary hot water around
the boiler and the plated water to water heat exchanger.
The burner will automatically light to maintain the
temperature of the heatbank.
When hot water is no longer required, the appliance will
continue to operate until the heatbank has returned to
temperature. Priority is always given to the production of
domestic hot water.
There are two hot water modes on the appliance. In the
standard mode the burner fires soonest to keep the thermal
store temperature high, maximising hot water comfort. In
ECO mode the thermal store temperature is allowed to fall
more before the burner fires, saving fuel.
Central heating mode
When central heating is required, the diverter valve will
open and the pump will energise in order to circulate
primary water around the heating system. The burner will
automatically light and the radiators will heat up to the
temperature set by the heating control thermostat.
Greenstar Heatslave II External model
Installation of a
Greenstar Oilfit
RS flue system
Applications
The outputs offered by the range ensures installation
exibility, making Greenstar oil-fi red boilers ideally suited
to many sizes of domestic property
The Greenstar Heatslave II will accept pre-heated DHW
to 60ºC from sources such as solar and biomass. They
are ideally matched to our range of Greenskies solar
thermal panels.
Fluing
The indoor appliance can be used with
either a room sealed concentric flue or
conventional (open) flue. A flexi-flue liner kit is available to
enable the appliance to be flued via a chimney. The room
sealed flue ensures quiet operation.
The external appliances utilise a balanced flue system in
order to minimise the risk of lockouts caused by heavy winds.
A standard flue kit is included with every external boiler.
A plume management kit is available for both internal and
external boilers.
Greenstar Oilfit – the easy-fit fluing solution
Multiple fluing options with the ability to flue internal floor
standing boilers from the top, rear or side and external
boilers from the rear and side
Conventional flue via the adaptor kit or flexi-flue chimney
liner kit
Room sealed flue lengths using 80/125mm dia. flue up to
8m vertically and 6m horizontally. Plume kit lengths to 5m
Quick-to-install push-fit connections and telescopic options
which form a gas-tight seal and in most cases eliminate the
need to cut the flue
Easy-fit installation that requires no special tools when
fitting flue extensions, elbows and adaptors.