A signal must possess all three
attributes (account number, event code,
and zone code) to trigger a TWA
session.
For example:
4-2 Alarm 123456 activates a TWA session
4-2 Alarm 123466 does not activate a TWA
session
3.1.5 Line Identification
3.1.5.1 Caller ID
Default: 0
Selections: 0 to 3
0 Disable Caller ID.
1 Output Caller ID to Automation and Printer.
2 Output Caller ID to Printer only.
3 Output Caller ID to Automation and Printer only
on No Data Received or Data Error.
Caller ID still appears at the LCD when
1, 2, or 3 is selected.
3.1.5.2 Caller Name
Default: 0
Selections: 0 or 1
0 Disable Caller Name.
1 Send Caller Name to the printer only.
Caller Name still appears at the LCD
when 1 is selected.
3.1.5.3 DNIS (D6600 Only)
A Dialed Number Identification Service (DNIS)
number can be 4 to 11 digits. A 2000 DNIS number
database can automate communication settings.
Database-supported settings:
Handshake 1-8
Five-Digit
Six-Digit
4-1 Extended
4-2 Extended
Seven-Digit
4-1 Express
Pulse Wait
Digit Wait
Round Wait
Ademco High Speed
Checksum
BFSK Extended
3-1 Extended
3-1 Restore Report in
High Speed
Extended Format Report
in High Speed Format
Tone Duration
Handshake Wait
Default: 0
Selections: 0 to 1
0 Disable
1 Enable
2 Enable DNIS, database DNIS only
If enabled using 1, a DNIS number is sent to the
automation PC and the printer. If there is no DNIS
number or a DNIS error, the output DNIS D is
followed by zeros equaling the length of the previous
valid DNIS. The output contains four zeros if there
was no previous valid DNIS.
If enabled using 2, only valid DNIS numbers in the
database are processed. If no DNIS number, an
invalid number, or a DNIS number not in the database
is received, the system disconnects the call.
3.1.5.4 ANI (D6600 Only)
Default: 0
Selections: 0 or 1
0 Disable
1 Enable, use sequence DNIS+ANI when
DNIS is available
2 Enable, use sequence ANI+DNIS when
DNIS is available
3.1.5.5 DNIS Digits
Default: 0
Selections: 0 to 11
Use this option to set allowed DNIS digits. This
option works with Options 3.1.5.3 DNIS and
3.1.5.4 ANI to prevent invalid DNIS/ANI signals.
0 No preset DNIS digits. Auto identify
according to Option 3.1.5.3 and 3.1.5.4
1 to 4 4 DNIS digits
5 to 11 The number of allowed DNIS digits