3.1.9.3 Acron 3-8 Account Output (D6600 Only)
Default: 0
Selections: 0 or 1
0 The D6600 sends a three-digit account code
to the automation software.
1 The D6600 sends a leading space to the
automation software.
ACRON 3-8 format has a three-digit account code.
Setting this option to 0 allows the D6600 to send a
three-digit account code to the automation software in
AAA form. Setting this option to 1 allows the D6600 to
send a leading 0 to the automation software in 0AAA
form.
3.1.9.4 4-2 Format Output (D6600 Only)
Default: 0
Selections: 0 to 3
0 Sends a normal Bosch D6500 Mode output
as AAAAsEssXY
1 Sends AAAAsEsssY
2 Sends AAAAsXsssY
3 Strip alpha characters in zone when in
automation format.
For example, 1234 F9 appears as 1234 9,
or 1234 30 appears as 1234 30.
AAAA = the account number
E = the event code derived from the code X in Menu Item
3.1.8.1 Event 4-2 Digit 0 to Menu Item 3.1.8.16 Event 4-2
Digit F on page 36
XY = the two-digit reporting code
This option applies only to Pulse 4-2 and DTMF 4-2
formats and provides the flexibility to interface with
different automation software, so that the automation
software’s database can accurately interpret the 4-2
signal.
3.1.9.5 Output for Modem II/III Formats (D6600
Only)
Default: 0
Selections: 0 or 1
0 Sends a normal D6500 Mode output to the
automation software.
1 Sends the S protocol to the automation
software.
This option provides an extended S protocol in the
D6500 Mode so all Modem II and Modem IIIa
2
messages can be sent in SIA format to automation.
Refer to the D6600/D6100IPv6 Computer Interface
Manual (P/N: 4998122703) for S protocol in D6500
Mode.
3.1.9.6 Convert Pulse Account Number (D6600
Only)
Default: 0
Selections: 0 to 3
0 No change (default).
1 Add prefix 0 to pulse 3-1 and 3-2
2 Remove prefix 0 at pulse 4-1, 4-2, and 4-3
3 Add prefix 0 to pulse 3-1 and 3-2 and
remove prefix 0 at pulse 4-1, 4-2, and 4-3
3.2 Setting Default Line Configuration
3.2.1 Default Line Configuration from the
Keypad
2x
Exit from this option without
changing the line
configurations to the default.
All line configurations return
to the default values listed in
Menu Item 3.1.1.1 Tone 1 on
page 24.
repeatedly.
D
6
6
0
0
C
A
N
D
6
1
0
0IPv6
i
C
A
N
C
E
L
D
6
6
0
0
D
6
1
0
0
IPv6
1
1
D
6
6
0
0
D
6
1
0
0IPv6
i
0
0
D
6
6
0
0
D
6
1
0
0
IPv6
E
N
T
E
R
M
/
E
D
6
6
0
0
D
6
1
0
0IPv6
D
6
6
0
0
D
6
1
0
0IPv6
E
N
T
E
R
M
/
E
D
6
6
0
0
D
6
1
0
0
IPv6
Page view 37
1 2 ... 33 34 35 36 37 38 39 40 41 42 43 ... 48 49

Comments to this Manuals

No comments