Conettix D6600/D6100IPv6 |
Program Entry Guide | 6.0 Network Configuration
42
Bosch Security Systems, Inc. | 11/12 | 4998122702-07
6.2.4 COM1 Stop Bit
Default: 1
Selections: 1 or 2
Select the stop bit value for COM1.
6.2.5 Network Adapter
Default: 0
Selections: D6600: 0 to 3
D6100IPv6: 0 or 2
0 Disable network adapter connection.
1 Enable network adapter connection for
D6600 with D6680 or D6100IPv6.
2
3
Enable network adapter connection for
D6600 with D6682 or D6100IPv6.
Enable network adapter connection for
D6600 with D6686.
6.2.6 Network Encryption Enabled
Default: 0
Selections: 0 or 1
0 Disable COM1 Network Encryption.
1 Enable COM1 Network Encryption.
6.3 Network Automation Connection
This section details connecting the D6600 or
D6100IPv6 to the network using the COM4 port
(D6600) or integrated Ethernet port (D6100IPv6).
Parameters programmed in this section
override other COM3 settings
programmed in other sections.
If the PC running the automation
software is using DHCP to get an IP
Address, the server might change the IP
address. If this occurs, the automation
software can no longer communicate
with the receiver until the receiver is
programmed with the new IP address
assigned to the automation PC. To
avoid this, use a static IP address for
the PC running the automation software.
6.3.1 IP Address
Selections:
[IPv4] xxx.xxx.xxx.xxx
[IPv6]
xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx
The IP Address of the computer running the
automation software must be set to a unique value in
order to distinguish it from other stations in the
network.
“UP” key”∆” for “.”, and “DOWN” key for
“:”
6.3.2 Port
Default: 10000
Selections: 1 to 65535
This entry is reserved unless a COM4 and/or a COM1
network adapter is enabled (Section 6.1.5 or Section
6.2.5 is not set to 0) and Datagram 02 is enabled
(Section 6.8.6 is set to 1). When this entry is
available, set it to the port number of the computer
running the automation software.
Typically, the port numbers 0 to 1023
are reserved in UNIX systems for
specific applications. Use numbers
ranging from 2000 to 30000 to avoid
conflicts.
6.3.3 Polling Interval
Default: 30
Selections: 0 to 255
Designate the polling interval in seconds to the
automation software.
6.3.4 Retry Number
Default: 4
Selections: 0 to 5
Select the number of retransmission attempts in case
of communications trouble.
6.3.5 ACK Wait
Default: 04
Selections: 01 to 60
Enter the time (in seconds) the D6600 waits for the
ACK message from the automation software.