62 en | Configuration Integrus
IOM-INT | V1.1 | 2010.12 Installation and Operation manual Bosch Security Systems B.V.
7. Divide the signal delay difference by 33. The rounded off figure is the signal delay switch
position for that radiator.
8. Add delay switch positions to radiators under a balcony, if applicable (see section 7.4.3 )
9. Set the delay switches to the calculated delay switch positions.
Figure 7.5, Table 7.1, Table 7.3 and Table 7.4 illustrate the calculation of the extra master-
slave signal delay.
Figure 7.5 System with master and slave transmitter in multi purpose room
Table 7.3 Calculation of the master-to-slave signal delays
CAUTION!
Turn the delay switches carefully to a new position until you feel that it clicks into position, to
prevent that a switch is positioned between two numbers, which would result in a wrong
delay setting.
NOTICE!
When a master-slave configuration is used for rooms which are always separated, the delay
switch positions can be determined per system and the delay caused by transmission from
master to slave transmitter can be ignored.
Cable length
master-slave
transmitter
[m]
Cable signal
delay per meter
[ns/m]
Cable signal
delay [ns]
Signal delay
slave transmitter
[ns]
Master-to-slave
signal delay [ns]
50 5.6 50x5.6=280 33 280+33=313
R2
R1
R4
R6
R9
20m
R7
R5
R10
Tx2
R8
R3 Tx1
20m
30m
20m
50m
30m20m
20m
30m
30m
20m