5.3.1 Create/Modify Tour
To modify one of the settings, select the tour point by moving right, which will highlight the
line in green. The preset number will start flashing indicating this setting is now changeable
by toggling up and down.
Four (4) tours are programmable each with up to 32 steps. Each step can be individually
programmed with a preset position number (1 to 64) and a dwell time in seconds (1 to 240).
To change the dwell time, send another Right command which will start the dwell option
flashing, as before up and down changes this value.
To select Random or Default options, move the joystick to either end of the available options.
For presets, the random values are between 1 and 64. For dwell times, random and default
settings are between 1 and 240.
5.3.2 Random Tours
To make the random options work, a few limits must be set up which indicate the range of
presets available, and the time scale available for dwell times. For example, setting a preset
position as Random and the limits as 5 and 20 respectively, the camera moves to a random
preset position between 5 and 20 and waits there for the given dwell time, which can also be
random and operates in the same way. Alternatively, for the dwell there is a default option,
the value of which can also be changed to the users requirements.
Example of tour setup:
: PRESET : DWELL
-----------------------------------------------
1: 1 : 5
2: 2 :DEFAULT
3: RANDOM : 5
4: RANDOM :RANDOM
5: 5 : 5
Menu Item Description
NUMBER OF TOUR
POINTS
The number of tour points ranges from 1 to 32, with each point having an available
preset position and dwell time, programmable on the Create / Modify Tour page.
TOUR POINT SETTINGS Contains the default and random limit settings. The settings are separated into Dwell
and Preset sub headings. If a tour point is defined to use a random preset or random
dwell, the values remain within the bounds set on this page.
CREATE/MODIFY TOUR Shows a list of the individual tour points in a tabular fashion. The number of points
available is defined by the setting on the previous page. Up and down controls move the
highlighted line to the next or previous tour point respectively, moving on to the next
page if the cursor is moved past the end (see Section 5.3.1 Create/Modify Tour, page 27).
RANDOM TOURS Moves intelligently through the presets if the random option is chosen. It will not repeat
a given position until all preset in the selection have been visited.
Tour Setting Value
Min. Random Preset Position 5
Max. Random Preset Position 15
Min. Random Dwell Time 10
Page view 26