Axis Communications
23-5
The Sequence portion of the NVR web client PTZ page may appear or disappear when the page
is refreshed.
If the MJPEG quality level is set to 100 at high resolutions ( 1920x1200 for example ) then live
viewing problems ( high latency, momentary loss of video, etc) may be observed in a Victor
Client surveillance screen if that workstation is also trying to live view using the NVR web client.
To avoid the problem, either reduce the quality level or reduce the number of live viewing clients
that are running on the workstation. Also the FPS provided by the camera may drop dramatically
as a result of increasing the quality level to 95 or higher.
The Axis M5013 and M5014 have a single speed PTZ movement therefore the camera PTZ
movement is affected only by the interval between the start and stop commands from Victor
Client, not the speed values in the start command. The consequence is that PTZ movements
may be larger than desired. Refer to QC 9770 for more details.
The Axis M3204 and other models that have the exposure setting at “automatic” ( default ) will
reduce FPS to improve image quality when poor lighting conditions occur. To avoid the FPS
reduction when the lights are turned off in the room being viewed then change the exposure
setting from “automatic” to “hold current” however the consequence is that the image quality
could be very poor (dark).
A frame rate drop or a brief video loss may occur at the moment that lights are turned off in a
room being viewed when receiving MJPEG from Axis Day/Night cameras. To avoid the problem,
either use MPEG-4 or H.264 to receive the stream. .
The NVR Web client allows selection of 8 Kbps audio bit rate and AAC Audio Codec but not the
audio sampling rate.
Selecting the 8 Kbps audio bit rate setting will result in a loss of audio if the
sampling rate is 16 KHz or higher. Use the camera's own web interface to change the audio
sample rate to 8 KHz
if the 8 Kbps audio bit rate is selected. This limitation occurs on Axis
cameras that support AAC Audio Codec and the 16KHz (or higher) Audio Sample Rate.
Please
refer to Axis camera documentation for details.
After going to a PTZ preset position on an Axis P5512 camera, the NVR web client will report an
error although the camera actually goes to the preset position.
After enabling dry contact inputs, ensure that LAN connectivity to the camera is maintained
otherwise frequent NVR event log messages will be generated about
failed attempts to re-
establish
dry contact event streams and an infrequent reload of the Axis handler may occur due
to a race condition flaw in libcurl version 7.21.3.
The number of presets allowed is capped at 50 for the victor Client. When working with
encoders, only the first 32 presets function properly. Axis documentation claims each channel
can support 100; however this does not appear to be the case.
Note
Please refer to AXIS cameras release notes published on the AXIS website for more information
about AXIS cameras and limitations.