Bosch ITS-DX4020-G Specifications Page 32

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 31
32 en | Configuration GPRS/GSM IP Communicator
F01U133268 | 03 | 2010.05 Installation and Operation Guide Bosch Security Systems, Inc.
4.3.2 Medium Security Application
Polling times are typically 1 to 4 hours. Path integrity is important, and short interruptions in
network service might be indicated at the premise and central station. The following Medium
Security Application recommendation assumes the ITS-DX4020-G is the primary
communication device with no backup.
Control Panel Settings
Poll Rate: 3 hours
ACK Wait: 300 sec (5 min)
Retry Count: 5
ITS-DX4020-G Settings
GPRS ACK Timeout: ACK wait (300 sec) x 2 = 600 sec
By setting the GPRS ACK timeout less than the retry count, the ITS-DX4020-G can
reconnect to the network if the carrier dropped the connection or for short maintenance
interruption outages.
GPRS Session Timeout: Must be greater than control panel poll time (3 hours) + ACK
wait (5 min) x Retry Count (5) + ACK Wait (5 min) = 3 hours and 30 min. The GPRS
session timeout default setting of 4 hours is acceptable.
D6x00 Receiver Settings
Control Panel Poll Rate: 4 hours
ACK Wait: 15 sec
NOTICE!
If you use a control panel poll rate of 4 hours, change the default GPRS session timeout to
5 hours. Ensure that your SIM service provider’s session timeout is greater than 5 hours.
Check the information that came with the SIM card. If the carrier’s session timeout is less
than your GPRS session timeout, the communication path is dropped by the carrier and the
event message is not received until a new connection is made, delaying your event messages
from being delivered when expected. To ensure the communication path is not dropped, set
the poll rate to less than the carrier timeout (for example, 2 hours).
NOTICE!
To set the control panel poll rate by the hour, ensure that the D6x00 Receiver has D6200CD
V1.35 firmware or later.
Because the Bosch D6x00 Receivers only have hours and seconds settings, the receiver would
have to be set to 4 hours instead of 3 hours and 30 min. The receiver can only support up to
255 sec maximum for the ACK wait time.