Figure 3.1 Wiring Diagram for Typical D9210C installation
3.2.3 Door Contact (Onboard) Point
ZN+, COM
Description. The interface module monitors the sensor loop for normal, shorted, or open
conditions. This loop is provided for a door contact. The maximum distance the door contact
may be remoted from the interface module is 500 feet. The door contact can be programmed
as a perimeter, interior, or 24 hour burglar alarm point.
NOTICE!
Do not install or replace an interface module while it is connected to live power circuits. The
interface module should be powered down until it is ready to be tested.