22 en | Installation Access Control Interface Module
F.01U.215.244 | 05 | 2012.06 Installation and Operation Guide Bosch Security Systems, Inc.
Refer to Section Figure 3.7 Power Supply and SDI Connections, page 23 for the following
connections:
SDI Connection
PWR. Connect the red wire to the SDI terminal. The red wire provides power to the interface
module and buzzers.
A PANEL DATA. Connect the yellow wire to the SDI terminal. The yellow conductor from the
control panel connected to this terminal.
B PANEL DATA IN. Connect the green wire to the SDI terminal. The green conductor from the
control panel is connected to this terminal.
COM (Common). Connect the black wire to the SDI terminal. The black conductor provides
electrical common between the interface module and the power source.
NOTICE!
Always ensure a common terminal connection exists from the interface module to the control
panel so the power supply and control panel have the same ground reference. Use any
common terminal on the interface module silk screen for connections.