Page view 22
Access Control Interface Module Installation | en 23
Bosch Security Systems, Inc. Installation and Operation Guide F.01U.215.244 | 05 | 2012.06
Figure 3.7 Power Supply and SDI Connections
3.2.11 Programming and activating the interface module
Description. The interface module needs to be assigned to an area before it can communicate
properly with the control panel. In addition, the address settings and the power need to be
connected.
The rotary settings in Section Table 3.4 D9210C Rotary Switches, page 21 determine the
address of the interface module. At the top of the ACCESS Control Interface Module Program
Record Sheet, the address number noted next to the rotary settings in
Section Figure 3.6 D9210C Rotary Switches, page 21 will determine which parameters for
the door controller are sent.
NOTICE!
It is very important to include the strike current. Bosch Security Systems recommends use of
an auxiliary power supply to isolate door controls and ensure the integrity of the system.