Conettix D6600/D6100IPv6 | Program Entry Guide | 2.0 CPU Configuration
Bosch Security Systems, Inc. | 11/12 | 4998122702-07
2.4.11 Modem IIe Fire
Default: 1
Selections: 0 or 1
0 Fire messages are sent to the automation
PC as standard alarms, troubles, and
restorals.
1 Fire messages are sent to the automation
PC with the digit character codes as shown
in Table 3 (refer also to the
D6600/D6100IPv6 Computer Interface
Manual [P/N: 4998122703] for the digit
character codes).
BFSK and Modem IIe
/Modem IIIa
2
Fire Bit
Examples
Some control panels offer enhanced fire messages in
BFSK, and Modem IIe
and Modem IIIa
2
formats. This
entry determines how the D6600/D6100IPv6 presents
BFSK, or Modem IIe and Modem IIIa
2
fire messages
to the automation PC (see Table 3 ). This entry has
no affect on how the messages print.
Table 3: BFSK, Modem IIe/IIIa
2
, or Modem4 Fire Bit Examples
FIRE ALARM
h1rr1ssssssaaaasFssszt h1rr1ssssssaaaasAssszt hlrrlssssssaaaasFspppt hlrrlssssssaaaasAspppt
FIRE ALARM
(Cross Point)
hlrrlssssssaaaasFspppt hlrrlssssssaaaasAspppt
FIRE
SUPRVISION
hlrrlssssssaaaaGsspppt hlrrlssssssaaaasTspppt
FIRE TROUBLE
h1rr1ssssssaaaaGssszt h1rr1ssssssaaaasTssszt hlrrlssssssaaaaGsspppt hlrrlssssssaaaasTspppt
FIRE ALM
RESTOR
hlrrlssssssaaaaHsspppt hlrrlssssssaaaasRspppt
FIRE TBL
h1rr1ssssssaaaaHssszt h1rr1ssssssaaaasRssszt hlrrlssssssaaaaHsspppt hlrrlssssssaaaasRspppt
FIRE ALARM
<header>[#aaaa|NriaFAppp] <header>[#aaaa|NriaBAppp] <header>[#aaaa|NriaFAppp] <header>[#aaaa|NriaBAppp]
FIRE ALARM
(Cross Point)
<header>[#aaaa|NFMppp] <header>[#aaaa|NBAppp]
FIRE
<header>[#aaaa|NriaFSppp] <header>[#aaaa|NriaBTppp]
<header>[#aaaa|NriaFTppp] <header>[#aaaa|NriaBTppp] <header>[#aaaa|NriaFTppp] <header>[#aaaa|NriaBTppp]
FIRE ALM
<header>[#aaaa|NriaFHppp] <header>[#aaaa|NriaBRppp]
RESTOR
<header>[#aaaa|NriaFRppp]
<header>[#aaaa|NriaBRppp]
<header>[#aaaa|NriaFJppp]
<header>[#aaaa|NriaBRppp]