D6200 cannot
connect to the
D6600/
D6100IPv6.
D6200 serial
connection is
defective, missing, or
incorrect serial cable.
Ensure that the cable between the PC and the D6600/D6100IPv6 is
null-modem. Also ensure that the cable is not damaged. Inspect all
pins on the D6600/D6100IPv6, PC, and serial cable.
Ensure that the null-modem cable is connected to the correct COM
port of the PC (as per the D6200 COM setting; COM1 through COM8).
COM settings do not match. In the D6200, under the Settings Menu,
select COM SETTINGS. Confirm that all settings match the
configuration of the D6600 Host Programming Parameters (Menu Item
4.5 Parameters).
On the D6600, ensure that Menu Item 4.5.9 RS-232 Direct Access
Permission is set to 1.
If upgrading software, ensure that Menu Item 4.5.7 Software
Programming Enable (on the D6600/D6100IPv6) is set to 1.
Notice! If Software Programming Enable is set to zero (0),
communication between the D6200 and the D6600 is successful but
the upgrades fail.
If using COM4 through a direct connection, check that Menu Item 6.1.5
COM4 Network Adapter is set to 0.
If using COM1 through a direct connection, check that Menu Item 6.2.5
COM1 Network Adapter is set to 0.
Port conflicts with other applications on the host PC.
Reboot the PC and restart the D6200 with no other applications
running.
Defective CPU terminator card.
Defective CPU card.
Defective PC COM port.