Bosch D9412GV2 User Manual Page 49

  • Download
  • Add to my manuals
  • Print
  • Page
    / 74
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 48
D9412GV2/D7412GV2 | Operation and Installation Guide | 10.0 Off-Board Relays
.
Bosch Security Systems, Inc. | 5/05 | F01U003641B 49
Figure 21: D8129 Connections to the D7412GV2
Pin
Battery
amming
E CONNECTIONS
POWER +
DATA BUS A
DATA BUS B
COMMON
ZONEX OUT 1
ZONEX IN 1
32
31
30
29
28
27
NOT USED
26
25
NOT USED
EX POWER +
24
X COMMON
23
D5200/D5360
PROG CONN
2
3
3
1234567 8
1
DATA
AUX
GND
1 - D8129 OctoRelays for relay numbers 1 to 64.
Connect OctoRelays in parallel.
2 - Power limited
3 - Supervised, power limited
10.1.1 Configuring the D8129 OctoRelay
Five switches on the OctoRelay determine the relay
numbers for the eight relay outputs (
Error! Reference
source not found.
).
Table 18: D8129 OctoRelay Switch Settings
Panel Relay
Number
D8129 OctoRelay
Switch Setting
On Panel, Connect
D8129 to:
1 to 8 Off-On-On-On-On Zonex 1 Terminal 28
9 to 16 On-Off-On-On-On Zonex 1 Terminal 28
17 to 24 Off-Off-On-On-On Zonex 1 Terminal 28
25 to 32 On-On-Off-On-On Zonex 1 Terminal 28
33 to 40 Off-On-Off-On-On Zonex 1 Terminal 28
41 to 48 On-Off-Off-On-On Zonex 1 Terminal 28
49 to 56 Off-Off-Off-On-On Zonex 1 Terminal 28
57 to 64 On-On-On-Off-On Zonex 1 Terminal 28
D7412G Maximum
65 to 72 Off-On-On-On-On Zonex 2 Terminal 26
73 to 80 On-Off-On-On-On Zonex 2 Terminal 26
81 to 88 Off-Off-On-On-On Zonex 2 Terminal 26
89 to 96 On-On-Off-On-On Zonex 2 Terminal 26
97 to 104 Off-On-Off-On-On Zonex 2 Terminal 26
105 to 112 On-Off-Off-On-On Zonex 2 Terminal 26
113 to 120 Off-Off-Off-On-On Zonex 2 Terminal 26
121 to 128 On-On-On-Off-On Zonex 2 Terminal 26
10.1.2 Relay Outputs
Relay outputs can activate when you are
setting the OctoRelay switches or
programming the control panel.
Disconnect equipment connected to relay
outputs when you perform these functions.
Each OctoRelay output provides a Form C dry contact
rated for 1.0 A at 12 VDC. Normally-open, common,
and normally-closed terminals are available for each
relay output. When an individual output is activated,
there is continuity between the normally-open and
common terminals. When the output is not activated,
there is continuity between the normally-closed and
common terminals.
10.1.3 Installation
Set the switches on the OctoRelay before installing it in
the enclosure. Refer to Section 10.1.1 Configuring the
D8129 OctoRelay on this page.
Install the OctoRelay in the enclosure with the control
panel (Figure 2 on page 9) or in an adjacent enclosure
that is no more than 1.5 m (5 ft.) from the control
panel. Use 1.5 mm (16 AWG) to 0.8 mm (22 AWG)
wire.
Page view 48
1 2 ... 44 45 46 47 48 49 50 51 52 53 54 ... 73 74

Comments to this Manuals

No comments