Parameter Value Description
Tamper (for GV4 ([v1.0.x or
higher] control panels)
0 = Disabled
1 = Enabled
When enabled, allows tamper
and tamper restore
conditions to be reported to
an SDI2 control panel.
Notice!
Only control panels with a
SDI2 bus connection to the
B450 can report a tamper
condition.
IPv4 DNS Server IP Address IPv4 address format (0.0.0.0) The B450 uses the DNS
server addresses supplied by
the cellular network when the
Primary DNS Server address
option is configured as
0.0.0.0. If the address is not
configured as 0.0.0.0, the
B450 installs the Primary DNS
Server address.
Web access password Enter a 4 – 10 character
password to access module
programming Do not use the
characters ; or !
The web access password is
used to allow access to
module programming. For a
B450 module, the password
controls configuration from
the USB menu and SMS text.
TCP/UDP Port Number 1 to 65535 (7700) Sets the source port for the
B450.
Alternate IPv4 DNS Server IP
Address
IPv4 address format (0.0.0.0) If the address is not
configured at 0.0.0.0, the
B450 installs the Alternate
DNS Server address.
TCP Keep Alive Time 0 – 255 sec (45) This parameter determines
how long to wait between
transmissions to keep an idle
TCP connection to a remote
host from terminating due to
inactivity.
IPv4 Test Address IPv4 address format (0.0.0.0) The IPv4 Test Address is used
by the module to ping an
internet address as part of
the IP diagnostics.
IPv6 Test Address IPv6 address format (0.0.0.0) The IPv6 Test Address is used
by the module to ping an
internet address as part of
the IP diagnostics.