Callout Description
1 - D6600 Number 1
2 – D6600 Number 2
3 – Null Modem cable
4 – D6686/D6682/D6680 Number 2
5 – A/B Network switch
6 – Network switch
7 – D6686/D6682/D6680 Number 1
Another necessary programming parameter is an Alternate MAC Address. The Alternate MAC
Address function allows a switch between the D6686/D6682/D6680 modules to occur without
the network detecting that anything changed. Program the D6686/D6682/D6680 modules as
follows:
1. Program D6686/D6682/D6680 Number 1 as described in the module’s installation guide
for all parameters including Channel 1. Use Port 7700 as the default port number (this
port can be different as described in the installation guide). Program Channel 2 with the
same settings that are in Channel 1. Change the port number to any value other than the
port number assigned to Channel 1 (any value between 2000 and 10000). If using
encryption, perform the setup described in the mdoule’s installation guide. Save the
settings and exit the telnet session.
2. Write down the MAC Address of D6686/D6682/D6680 Number 1. This will be needed
during the setup of D6686/D6682/D6680 Number 2.
3. Program D6686/D6682/D6680 Number 2 with the same settings that you entered into
D6686/D6682/D6680 Number 1, do not save and exit but continue to Step 4.
i
Notice!
Do not connect both D6686/D6682/D6680 modules to the network at the same time.
4. After completing these settings, you must do two additional settings:
Under Expert Settings (Menu Item 5), locate the Alternate MAC Address prompt. At
this prompt, enter the MAC Address of D6686/D6682/D6680 Number 1.
Under Security Settings (Menu Item 6), change the prompt for Alternate MAC to a Y
so that the D6686/D6682/D6680 uses the Alternate MAC Address programmed in
Menu Item 5. Save the settings.
5. Connect the cabling as shown in the graphic above. Ensure that there is a switch box for
the network cable connection.
6. In the D6200 software, add two receivers as follows:
Add the first receiver and name it Primary Receiver, with the Receiver IP Address and
Receiver Port number for Channel 1 of the D6686/D6682/D6680.
Add the second receiver and name it Backup Receiver with the Receiver IP Address
and Receiver Port number for Channel 2 of the D6686/D6682/D6680.
7. In the D6200 software, select the Primary receiver when programming changes are
needed. After all program settings are sent to the Primary Receiver, change the receiver in
the Connection settings to Backup Receiver and send the same parameters to the backup
receiver.
52 en | Network Communications
Conettix Communications Receiver/
Gateway
2012.11 | 08 | 4998122704 Installation and Operation Guide Bosch Security Systems, Inc.