DS7400XiV4-EXP | User Guide | 7.0 Emergency Procedures EN | 21
Bosch Security Systems | 6/05 | 4998154961B
Installation Considerations
Proper location of detection devices is one of the most
critical factors in a fire alarm system.
Here are some general considerations:
Do not install smoke detectors in “dead air” spaces
or close to ventilating or air-conditioning outlets
because smoke might be circulated away from the
detector. Locations near air inlets are favored.
Avoid areas subject to normal smoke
concentrations such as kitchens, garages, or near
fireplaces.
Do not install smoke detectors where normal area
temperatures are above 38 °C (100 °F) or below 0
°C (32 °F).
Avoid areas of high humidity and dust
concentrations.
Install ceiling-mounted detectors so the edge is no
closer than 10 cm (4 inches) from any wall.
Place the top edge of wall mounted detectors from
10 to 30 cm (4 to 12 inches) from the ceiling.
Figure 4: Smoke Detector Installation
1
2
3
4
5
4
4
1 – Rec Room
2 – Dining Room
3 – Kitchen
4 – Bedroom
5 – Living Room
* – Smoke Detector
Install smoke detectors between sleeping areas and
family living areas.
7.9 Emergency Keypad Alarms/
Silencing Alarms
The Emergency Alarm Keys [ ], [ ], and [ ] can
generate Fire, Special Emergency, and Panic Alarms if
programmed by the installer. Ask your installing
company to explain the function of these keys. To use
an Emergency Key, you must press the button for
two seconds to generate an alarm. Use the
Disarming Command Sequence to cancel or silence
these alarms.
If the Emergency Alarm Keys are to be used, label the
keys to signify their functions.
Label the left-most key as the Fire key. This is the only
key that can be designated as the Fire key.
Label the middle key as the Special Emergency key.
Label the right-most key as the Panic key.
On RF keyfobs, the Panic signal is sent to your security
system when two keys are held down simultaneously
for at least three seconds.
Figure 5: Emergency Keypad Alarms
1 23
456
789
0
*
#
12345678
910
11
12 13
14
15
16
Armed
Status
Power
Fire
Perimeter
Supervisory
Bell Silenced
Trouble
System
Reset
Bypass
No
Entry
Perimeter
Only
Off
On
Armed
Status
Power
Fire
1 23
456
789
0
*
#
On
No
Entry
System
Reset
Bypass
Only
Perimeter
Off
TEST WEEKLY
1 – Emergency Keys
Page view 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 39 40

Comments to this Manuals

No comments