DS7400XiV4-EXP | User Guide | 10.0 Testing Your System EN | 30
Bosch Security Systems | 6/05 | 4998154961B
10.5 Event History Readback
The History Buffer stores the last 400 events in memory. The text keypad can display all of these events. The
LED keypad only displays the zones (1 to 16) that alarmed since the last Event History Readback. If you perform
this test from a Master keypad, the keypad must be in Single Partition Mode. The RF3341 keypad cannot display
history events.
Table 29: Event History Readback
Type of Test Command Sequence What Happens What To Do
Event History
Readback
[PIN][#][8][9]
The last event to take place is displayed. *
The zone LEDs flash for any zones that alarmed
since the last Event History Readback. **
Note: To read the System Error Displays, follow the
instructions in Section 9.0 Error Displays.
Scroll through the events
using the [9], [6], and [#]
keys. *
Exit from Event History
using [PIN][#].
* Text keypad only ** LED keypad only
Scrolling through the History Events (Text Keypad Only)
Press [#] to scroll back through the history line by line.
Press [9] to scroll in reverse chronological order by event.
Press [6] to scroll back through the events (toward the most recent) by event.
Each event consists of two or three lines or display screens. The first line/screen is the event title and user. The
second line/screen is the date of the event or the change being made. If there is a third line/screen, it will be the
date of the change.
To exit the Event History Mode, press the [*] key or wait 20 seconds and the keypad exits automatically.
When performing Event History Readback from a Master keypad, each area displays its own history.