Bosch GREENSTAR HEATSLAVE II EXTERNAL 12/18 Service Manual Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
17
Technical data
Boiler
Greenstar Heatslave II
External 12/18
Greenstar Heatslave II
External 18/25
Greenstar Heatslave II
External 25/32
Height
950mm 950mm 950mm
Width
640mm 640mm 640mm
Depth
770mm 770mm 770mm
Weight – lift
151kg 154kg 158kg
ErP Seasonal space heating energy effi ciency class
A / 91% A / 90% A / 91%
ErP Water heating energy effi ciency class
BBB
ErP Water heating efficiency – declared load profile
XL XL XL
2009 SEDBUK effi ciency
89.4% 89.2% 89.0%
Primary water capacity (total)
62 litres 63 litres 64 litres
Available pump head (20°C difference) at maximum output
4.7m 4.0m 4.2m
Maximum permissible sealed system operating pressure
in accordance with WRAS guidelines
2.5bar 2.5bar 2.5bar
Maximum fl ow rate for a 40ºC ∆T over a 90 litres draw off
15 ltr/min* 18 ltr/min* 22 ltr/min*
Minimum inlet pressure (dynamic) for optimum fl ow rate
1.5bar 1.2bar 1.6bar
Exit fl ue gas mass fl ow
29kg/hr 40kg/hr 51kg/hr
Fuel line (compression)
10mm 10mm 10mm
CH fl ow
22mm 22mm 28mm
CH return
22mm 22mm 28mm
Water main inlet
15mm 15mm 15mm
DHW outlet
22mm 22mm 22mm
Condensate connection
21.5mm polypropylene 21.5mm polypropylene 21.5mm polypropylene
Electrical power supply voltage
230V AC 230V AC 230V AC
Frequency
50Hz 50Hz 50Hz
Maximum power consumption
184W 209W 233W
Part load power consumption†
44W 47W 48W
CH control range
50/82ºC 50/82ºC 50/82ºC
Heat store control range
55/84ºC 55/86ºC 55/88ºC
Boiler manual reset overheat thermostat set point
105ºC 105ºC 105ºC
Flue reset overheat thermostat set point
110ºC 110ºC 110ºC
Tank manual overheat reset thermostat set point
95ºC 95ºC 95ºC
Maximum hearth temperature
<100ºC <100ºC <100ºC
Output to central heating
12 - 18kW 18 - 25kW 25 - 32kW
Oil burner
Riello RDB2.2** Riello RDB2.2** Riello RDB2.2**
Plug-in timer
9
(optional)
9
(optional)
9
(optional)
Weather load/compensation
999
Plume management maximum length
5,000mm 5,000mm 4,000mm
Appliance protection rating
IP 45 IP 45 IP 45
Noise output level
N/A N/A N/A
*Restricted DHW flow rate. **Suitable for kerosene (28 sec oil) only. †Power consumption excluding pump.
Page view 16