Bosch Greenstar 12i Service Manual Page 67

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 66
FAULT FINDING AND DIAGNOSIS
6 720 644 743b (2011/08)
67
7.2 BOILER FUNCTION
Fig. 124 Boiler function
NO
YES
MAINS
POWER
SUPPLY
ON
BOILER
DEMAND
Fan to
start
speed.
Pump ON.
IGNITION
SEQUENCE
(see detai )
BLUE
LIGHT
ON
BURNER
LIT?
GREEN
FLAME
LIGHT
ON
Stop spark
and gas.
Wait
10 seconds
5th
attempt?
LOCKOUT
10 second
stabi isation
period.
Fan
modu ation
to achieve
set
temperature
(40-82°C)
END OF
BOILER
DEMAND
Gas va ve
OFF
Pump run 3
minutes
Fan run 30
seconds
Over temperature shut-
down if water tempera-
ture is 5°C above set
va ue.
Gas va ve OFF.
Fan overrun
30 seconds
3 minute pump
over run
Spark
ignition
and gas
4 seconds
NO
YES
Room
thermostat and/or
mains
programmer ON
(or ink fitted at
ST10)
AND
Facia mounted
programmer (if
fitted) ON
AND
CH contro knob
ON
IGNITION SEQUENCE
6720644743-39.1Wo
Page view 66