36
Greenstar Heatslave II combi boiler range
horizontal fluing options (internal models)
Flue diameter 125mm
Greenstar Heatslave II series
Minimum fl ue length 160mm
Maximum fl ue length Rear exit 6,000mm
Side exit 5,000mm*
High level 5,000mm**
*Length includes 90°bend inside cabinet.
** Length includes 2x90° bends, one within the cabinet and one before the
telescopic flue kit.
Greenstar Heatslave II components
The following criteria should be noted when planning
the installation:
The concentric fl ue system must be inclined at
3º (52mm per metre) from the appliance, to allow
condensate to drain back into the boiler
A white plume of condensation will be emitted from
the terminal because the appliance operates at high
effi ciency. Care must be taken when selecting the fl ue
terminal position
To achieve a maximum fl ue length, one of the extension
ue kits will need to be cut so that the permitted
maximum fl ue length is not exceeded
Note: The short fl ue extension (600mm) may be used
as an alternative to the standard 1,000mm extension
on 80/125mm fl ue installations as required up to the
maximum fl ue lengths stated (Part No. 7 716 190 097).
The Greenstar Heatslave II combi boiler range has a 125mm
diameter telescopic horizontal room sealed flue system
including a plume management kit.
Horizontal room sealed flue –
rear exit flue lengths
Note: The maximum fl ue length must be reduced by the
following amounts for each additional bend used.
45º bend 90º bend
80/125mm fl ues
500mm 1,000mm
Part No. Description
125mm diameter
7 716 190 064
Standard telescopic flue kit
(460 - 670mm)
7 716 190 062
Short telescopic flue kit
(350 - 460mm)
7 716 190 033 1,000mm flue extension
7 716 190 097 600mm short flue extension
7 716 190 034 90º bend
7 716 190 035 45º bends (pair)
7 716 190 101
Flue damper
7 716 190 050 Flue terminal guard
7 716 190 105
Infill plate kit for high level
horizontal flues