Bosch Solution 64 Specifications Page 42

  • Download
  • Add to my manuals
  • Print
  • Page
    / 108
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 41
Solution 64
|
Installer Guide
|
Input Programming
7-2
Bosch Security Systems | 11/05 | BLCC110I
The keypad will display the following zone array information
for Zones 97 to 112.
9990000000000111 1
7890123456789012 0
---------------- 0
Press  OK or MENU
The keypad will display the following zone array information
for Zones 113 to 128.
1111111222222222 1
3456789012345678 0
---------------- 0
Press  OK or MENU
When nished press [OK] or [MENU] to exit.
Inputs > Commands >
Bypass Zones
-
-
MENU 3-0-2
This menu allows users with the appropriate access level to
manually bypass zones eectively removing them from the
area for the current arming cycle. All zone types including
24hour zones can be bypassed.Bypassed zones will be reset
when the area is turned o or disarmed.
Enter [MENU] + [3] + [0] + [2]. A list of zones that can be
bypassed will display on the keypad. A tick displayed on the
right side of the zone name indicates that the zone is already
bypassed.
Zn001 Zone 1 Name
Zn002 Zone 2 Name
Zn003 Zone 3 Name
Press  OK or MENU
Using the up and down arrow keys highlight the zone that you
want to bypass, then press [OK]. Alternatively, you can enter
the zone number that you want to bypass, then press [OK]. If
the zone is bypassed, the keypad will prompt:
Zone 1 Name Zn001 is
bypassed. To un-bypass
Press OFF.
Press OK or MENU
If the zone is not bypassed, the keypad will prompt:
Zone 1 Name Zn001 is
un-bypassed. To bypass,
Press ON.
Press OK or MENU
Press [ON] or [OFF] to toggle the zone(s) bypass state then
Press [OK] to save and exit or press [MENU] to exit without
saving.
Repeat steps 1 to 4 to bypass or un-bypass additional zones.
3)
4)
5)
1)
2)
3)
4)
5)
Inputs > Commands >
Set Chime Zones
-
MENU 3-0-3
This menu allows you to program zones to be monitored when
chime mode is activated. Chime mode is ideal for monitoring
a front door in a shop, a pool gate or other entrance points.
To sound the keypad buzzer when a chime zone is opened
(faulted) See MENU 6-1-5 — Beeper Options. To activate
Chime mode enter PIN + [MENU], select the Commands option
and use the arrow keys to scroll to the Chime On/O menu.
Chime mode only works when the area is disarmed.
Enter [MENU] + [3] + [0] + [3] and use the up and down arrows
to highlight the area from the list then press [OK].
Use the up and down arrow keys to highlight the zone(s) you
want to program as Chime Zones then press [OK].
Alternatively, you can enter the zone number directly then
press [OK]. A tick mark displayed on the right side of the zone
name indicates that the zone is already set for chime.
Zn001 Zone 1 Name
Zn002 Zone 2 Name
Zn003 Zone 3 Name
Press  OK or MENU
One of the following messages will be displayed depending on
the current zone programming.
Zone 1 Name Zn001
Zone Chime is OFF
To turn ON, Press ON
To Go Back Press OK
Zone 1 Name Zn001
Zone Chime is ON
To turn OFF, Press OFF
To Go Back Press OK
Press [ON] or [OFF] to toggle the zone to be monitored when
Chime Mode is turned on then press [OK] to save and exit or
[MENU] to exit without saving.
1)
2)
3)
4)
Page view 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 107 108

Comments to this Manuals