2-2
Bosch Security Systems | 11/05 | BLCC110I
Solution 64
|
Installer Guide
|
Section 2 - Installing the Hardware
Panel Address Select
The Solution 64 pcb has three DIP switches (called Panel Node
Select) that must be set. In a multi-panel system, each control
panel (Node) must to be set to a unique address.
Panel NODE Select DIP Switch Address Settings
Panel to Address S1 S2 S3
Panel 1 Off Off Off
Panel 2 On Off Off
Panel 3 Off On Off
Panel 4 On On Off
Panel 5 Off Off On
Panel 6 On Off On
Panel 7 Off On On
Panel 8 On On On
Table 3 Panel Node Address Select
i
Note
The node switch should be left at Panel 1 position for Solution
64. OFF-OFF-OFF
The Graphic Keypad has 20, silicone rubber push button keys.
The buttons allow you to input instructions and navigate the
menu screens as required. Some buttons have a secondary
function which is activated by holding them down for two
seconds.
Each buttons function is described below
Keypad Button Functions
Key
Description
to
The numeric keys allow you to enter
numbers when required
Use the [MENU] and the numeric keys
to enter commands. The [MENU] key
is also used to go back one level when
navigating through menus or to exit a
programming location without saving
changes.
The [ON] key allows you to turn an area
or output on. To turn all areas on at the
same time when the system has been
partitioned, press and hold the [ON]
key for two seconds.
The [PART] key allows you to turn an
area Part On. This key can also be used
to bypass a zone or multiple zones
when you press and hold for two
seconds.
The [OFF] key allows you to turn an area
or output o. To turn all areas o at the
same time when the system has been
partitioned, press and hold the [OFF]
key for two seconds.
The [OK] key allows you to save any
changes and exit the command.
Key
Description
The [MAIL] key allows you to read
stored mail. This key can also be used
to initiate a dialler test when you press
and hold for two seconds.
The [] key allows you to move the
cursor to the left when programming
text or telephone numbers.
The [] key allows you to move the
cursor to the right when programming
text or telephone numbers.
The [] key allows you to navigate
through menus or to toggle characters
when programming text or telephone
numbers.
The [] key allows you to navigate
through menus or to toggle characters
when programming text or telephone
numbers. Pressing the [] key when the
area is disarmed will display any current
trouble conditions.
+
for 2 sec
Pressing the 1 and 3 keys together and
holding them down for 2 seconds will
cause a Panic alarm to be triggered. If
programmed the sirens will sound and
the monitoring station will be notied.
+
for 2 sec
Pressing the 4 and 6 keys together and
holding them down for 2 seconds will
cause a Fire alarm to be triggered. If
programmed the sirens will sound and
the monitoring station will be notied.
+
for 2 sec
Pressing the 7 and 9 keys together and
holding them down for 2 seconds will
cause a Medical alarm to be triggered. If
programmed the sirens will sound and
the monitoring station will be notied.
Keypad Installation and Setup
The Solution 64 control panel can have a maximum of 8
keypads connected via the LAN terminals. Each keypad must
be set to a unique address before they will operate and you will
also need to set the keypad home address in MENU 6-1-3.
Set each keypad address using the table below as a guide.
i
Note
Only 1 Keypad can be assigned to each address.All Keypads are
supplied from the factory set to address 1. OFF-OFF-OFF.