Solution 64
|
Installer Guide
|
Comms Programming
9-8
Bosch Security Systems | 11/05 | BLCC110I
RAS Allowed
Callback Verify
Abort RAS On Alarm
Press  OK ON OFF MENU
Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
RAS Allowed
This option allows you to congure the panel via the
SolutionLink RAS upload/download software using a PC.
There are two dierent methods of connection avialable;
Direct Connect – via serial cable.
Remote Connect – via telephone line.
i
Note
See Direct Link and SolutionLink RAS Upload/Download
programming in Section 5 — Programming Overview for more
information.
Call Back Verification Required
Setting this option will force the panel to use call back verication for
all remote SolutionLink RAS sessions. See MENU 5-3-0 — Call back
Number for more information.
Terminate RAS On Alarm
If this option is programmed, the RAS connection between the panel
and the remote upload / download computer will be terminated if
panel registers an alarm that needs to be reported.
Answering Machine Bypass
Answering machine bypass allows you to establiish a RAS connection
to a panel when there is an answering machine or facsimile machine
connected on the same telephone line.
Using SolutionLink call the paneland let the phone ring no
more than 4 times before hanging up.
Wait a minimum of 8 seconds (but no more than 60 seconds)
before calling the panel again. This time the panel will answer
the incoming call as soon as it registers the rst ring and the
connection will be established.
Answer Incoming Call Only If Armed
Setting this option will prevent the panel from answering an
incoming call unless at least one area on the system is armed. If all
areas are o the panel will not answer the call. This option would be
useful in a busy oce when due to the large volume of incomming
calls answering machine bypass may not be eective.
Remote Program Editing Only When Disarmed
Setting this option will prevent a SolutionLink RAS connection to the
panel while any are is armed.
2)
3)
1)
2)
1)
2)
Allow User Functions’ Via Remote Access Software
Setting this option allows access to user functions via the RAS upload/
download software. If this option is not programmed, user functions
will be disabled.
Report RAS Start / End Sessions
Setting this option will cause the panel to report the start and end of
RAS programming sessions to the base station and the history log.
Comms > Remote Access >
DTMF Options
MENU 5-3-5
1 DTMF Arming Y
2 DTMF Disarming N
3 DTMF User Functions N
4 DTMF Quick Arm ([0] + [#]) Y
5 Reserved N
6 Reserved N
7 Reserved N
8 Reserved N
Press [MENU] + [5] + [3] + [5]. The keypad will display the
current DTMF options.
DTMF Arming
DTMF Disarming
DTMF User Functions
Press  OK ON OFF MENU
Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
DTMF Arming
Setting this option enables user to remotely arm one or more areas
on the panel using their PIN and a touch tone phone. This option
requires the Solution Interactive Voice module to be tted.
DTMF Disarming
Setting this option enables users to remotely disarm one or more
areas on the panel using their PIN and a touch tone telephone. This
option requires the Solution Interactive Voice module to be tted.
DTMF User Functions
Setting this option enables access to user DTMF functions using their
PIN and a touch tone telephone. This option requires the Solution
Interactive Voice module to be tted.
DTMF Quick Arm
Setting this option allows users and control room operators to
remotely arm the system using a touch tone phone without the need
for a PIN.
To arm the system call the number which the panel is connected
to and when the panel answer you will here 3 beeps in accending
frequency if the panel is in the disarmed condition. Press [0] + [#] to
arm. You will hear 3 beeps in decending order when the panel arms.
i
Note
All areas on the system will be armed regardless of there
condition when using the DTMF quick arm function.