System Power Options
System > Power >
AC Options
MENU 7-3-0
1 Display AC Fail Y
2 Report AC Fail Y
3 Use AC To Synchronise The System Clock Y
4 Random AC Report 2hour N
5 AC Fail After 1 hour N
6 Reserved N
7 Reserved N
8 Display Clock Trouble Y
This menu option allows you to congure the AC Mains Power
system options.
(*** System Wide Parameter ***)
Press [MENU] + [7] + [3] + [0]. The keypad will display the
current AC Options.
Display AC fail
Report AC Fail
Sync Clock To AC
Press  OK ON OFF MENU
Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
Display AC Fail
Setting this option will cause the panel to ash the Mains Power
icon as soon as the AC power supply has failed. If the power remains
missing continiously for 1 minute then a system trouble will be
registered on the keypad. When the AC power supply returns to
normal the Mains Power icon will remain on steady. If this option is
disabled then the system will not ash the Mains Power icon and no
system trouble will occur.
Report AC Fail
Setting this option will cause the panel to report an AC Fail to the base
station if the mains power has been missing for a period of 1 minute.
A restore report will be sent once the mains power has been restored
for one minute.
Synchronise System Clock to AC
Setting this option allows the panel to syncronise its internal clock
with the mains frequency (50hz). This option should be set unless the
panel is being used in an area where the mains power is unreliable.
Random AC Reporting 2hr
Setting this option allows the panel to randomly delay (up to 2 hours)
the AC Fail report. This option is used to prevent multiple Solution-
128 panels from reporting AC fail at the same time and should be left
disabled when using the Solution 64 panel.
Extend AC Fail To 1 Hour
Setting this option will cause the panel to only send an AC Fail report
to the base station if the power has been missing continuously for one
hour. The Mains Power icon will operate as normal.
1)
2)
3)
Display Clock Trouble
Setting this option will cause the panel to show a Date and Time
System trouble if the power is removed from the system for any
period of time such as when performing a system upgrade or service
work. If this option is disabled then no system trouble will appear and
you will need to remember to set the correct time when you re power
the system.
System > Power >
Battery Options
MENU 7-3-1
1 Display Battery Fail Y
2 Report Battery Fail Y
3 Execute Battery Testing On Arming Y
4 Arming Allowed On Low Battery Y
5 Reserved N
6 Reserved N
7 Reserved N
8 Reserved N
This menu option allows you to congure the standby Battery
system options. The system is constantly monitoring the
battery condition with a dynamic battery test carried out every
4 hours.
(*** System Wide Parameter ***)
Press [MENU] + [7] + [3] + [1]. The keypad will display the
current Battery Options.
Display Battery Fail
Report Battery Fail
Battery Test On Arming
Press  OK ON OFF MENU
Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
Display Battery Fail
Setting this option will cause the keypad to display a Trouble
condition when the panel detects that the standby battery is
disconnected or that its voltage is low. The trouble condition will
clear as soon as the panel has measured the battery voltage is 12.5
volts or greater.
Report Battery Fail
Setting this option will cause the panel to send a Low Battery report
to the base station when it measures the battery voltage has dropped
below 11.5 volts. A Low Battery Restore report will be sent when the
panel detects that the battery voltage is above 12.5 volts.
If the panel fails to detect the battery, or if it measures the battery
voltage below 10.2 volts, then a Battery Test Failed report will be sent.
A Battery Test restore will be sent when the battery is re-connected or
replaced.
Execute Battery Testing On Arming
Setting this option will cause the panel to perform an additional
dynamic battery test each time Area 1 is armed All On.
1)