Bosch Solution 64 Specifications Page 47

  • Download
  • Add to my manuals
  • Print
  • Page
    / 108
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 46
Solution 64
|
Installer Guide
|
Input Programming
Bosch Security Systems | 11/05 | BLCC110I
7-7
Inputs > Zone Properties >
Report Route
MENU 3-1-6
0 = Report Events To Log Only 1
1 = Report Events To Destination 1 + Log
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails +Log
This menu sets the Zone Report Route or Report Destination
for each individual zone in the system. All events such as
alarms and troubles for each zone will be reported according
to this menu setting. Each zone can only be assigned to one
report route from the list above.
Press [MENU] + [3] + [1] + [6] and use the up and down arrows
to highlight the Zone in the list then press [OK]. Alternatively,
you can enter the zone number directly and press [OK]. The
keypad will display the current Zone Report Route.
Report Route Zn001
01 - Dest 1 + Log
Press 0-9 OK or MENU
Use the up and down arrows to select the Report Route that
you want to assign the zone to.
Press [OK] to save and exit or press [MENU] to exit without
saving.
i
Note
At factory default all Zones are set to report to Destination
1 and the System Log. See the Zone Default Table for more
information on Zone default settings.
Inputs > Zone Properties >
Report Options
MENU 3-1-7
1 Lockout Dialer Y
2 Report Alarm Y
3 Report Trouble Y
4 Report Bypass Y
5 Reserved N
6 Reserved N
7 Report Restores Y
8 Delay Report N
The above options are programmable per zone.
Press [MENU] + [3] + [1] + [7] and use the up and down arrows
to highlight the Zone in the list then press [OK]. Alternatively,
you can enter the zone number directly and press [OK]. The
keypad will display the Report Options for the currently
selected zone.
Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
Lockout Dialler
Report Alarm
Report Troubles
Press  OK ON OFF MENU
1)
2)
3)
1)
2)
Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
Lockout Dialler
Setting this option will enable Dialler Lockout functionality for
the respective zone(s). All zones in the system can be individually
programmed for Dialler Lockout.
When enabled the zone will be allowed to transmit alarm reports
each time it is triggered provided that the Swinger Dialler count has
not been reached. If the zone is triggered and the Swinger Dialler
count has been reached then the zone will become locked out and no
further reports will be sent for that zone. Dialler lockout will be reset
on the next arming cycle.
See MENU 5-4-5 — Swinger Dialler to set the number of times a zone
is allowed to trigger before being locked out.
Report Alarm
Setting this option will enable the system to Report Alarm events
for the respective zone. All zones in the system can be individually
programmed to report alarms.
Report Trouble
Setting this option will enable the system to Report Trouble events
for the respective zone. A Trouble report will be sent if the zone is
left unsealled at the end of exit time. All zones in the system can be
individually programmed to report trouble events.
Report Bypass
Setting this option will enable the system to Report Zone Bypass
events for the respective zone. A Bypass report will be sent at the end
of exit time for zones which have been manually bypassed. All zones
in the system can be individually programmed to report Zone Bypass
events.
Report Restores
Setting this option allows the system to send Restore reports for
zones that have already sent a previous alarm or trouble report on the
same arming cycle.
Burglary Zone alarms and troubles restore when the zone
reseals or the area is disarmed.
24hr Zone alarms and troubles restore when the zone reseals.
Bypassed Zone restore when the area is disarmed.
Delay Report
Setting this option will cause the system to delay alarm reports for
the selected zone. This option can be enabled to allow a user to enter
their PIN and disable the report in case they have caused a false alarm.
If a PIN is not entered within the delay time, the system will trigger the
sirens and send the report as normal.
See MENU 5-4-6 — Burg Report Delay and MENU 5-4-7 — Fire Report
Delay to set the delay time.
If a PIN code is entered after the delay time has expired, and the sirens
are still sounding, the system will send the Alarm report followed by a
Cancel report.
3)
1)
2)
3)
Page view 46
1 2 ... 42 43 44 45 46 47 48 49 50 51 52 ... 107 108

Comments to this Manuals

No comments