Bosch D9112B Installation Manual Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 96
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
D9112B | Program Entry Guide | 2.0 Area Wide Parameters EN | 30
Bosch Security Systems | 2/04 | 74-06145-000-D
Selective Combinations of Account and Area
Opening and Closing Reports
You can eliminate
Area
Opening
and
Closing
reports from selected areas in the account by
programming
A# Area O/C
NO for those areas. If
an area that is not programmed for
Area
Opening
and
Closing
reports is the first to open, or the last to
close, only the
Account Opening
and
Closing
report is sent.
You can suppress
Area
Opening
and
Closing
reports from selected users by programming
A#
Area O/C
YES, then programming
L## Area O/C
NO for their authority level. If a user, not
programmed for
Area
Opening
and
Closing
reports, opens the first area in the account, or closes
the last area in the account, only the
Account
Opening
and
Closing
report is sent.
Combining Account and Area Opening and
Closing Reports
To send both Account openings and closings, and
individual Area openings and closings for all areas in
the account, program
A# Acct O/C
YES for all
areas in the account, program
A# Area O/C
YES
for all areas in the account, and program
L## Area
O/C
YES for the authority levels used in the areas.
Closing Reports: In this configuration, when areas
in the account are independently armed, each area
generates an
Area Closing
report. In addition,
when the last area is armed, it also generates an
Account
Closing
report.
Opening Reports: In this configuration, when the
first area in the account is disarmed, it generates an
Account
Opening
report along with an
Area
Opening
report. Then when the rest of the areas in
the account are disarmed, each area will generate an
Area
Opening
report.
Additional Opening/Closing Supervision Features
This section of the program also provides several
other features you can use to supervise opening and
closing activity by area.
Auto Close
,
Fail to Open
,
and
Fail to Close
all work independently of the
A#
Acct O/C
feature. To use these features however,
you must program O/C Windows.
Area
Default: 1
Selection: 1 to 8
Enter the area number you are programming.
A# Acct O/C
This program item determines if
Account Opening
and
Closing
reports are generated by this area. Program this
item the same for all areas in the account.
Default: No
Selection: Yes or No
Yes
Send
Opening
and
Closing
reports by account.
Use this selection if the panel reports to an automation system that cannot interpret multiple area
Opening
/
Closing
reports, or if
Modem Format
is programmed NO in the Phone category (BFSK
Format is in use and
Opening
and
Closing
reports are enabled).
An
Account
Opening
report is generated when the first area in an account is opened (disarmed).
After the
Account
Opening
report is sent, disarming other areas in the account does not generate
another
Account
Opening
report. An
Account
Closing
report is generated only when the last area
in an account is closed (armed).
Account
Opening
and
Closing
reports do not contain any area
information.
Note:
Opening and Closing Windows affect Account Opening and Closing reports: If an account opening or
closing is generated while an opening or closing window for this area is in effect, and
Disable O/C in
Window
is programmed YES, the report is not sent. Bosch Security Systems recommends that all areas
sharing the same account number use the same Opening and Closing Window times.
No
Do not send
Opening
and
Closing
reports by account.
Page view 29