D9112B | Program Entry Guide | 6.0 Passcode Worksheet EN | 67
Bosch Security Systems | 2/04 | 74-06145-000-D
User
Default: 1
Selection: 0 or 1 to 99
Enter the User number you are programming.
0101
0101
0101
User 0 is the Service Authority Level (Level
15). The Program Record Training Sheet
shows the functions enabled for Authority
Level 15.
You cannot change the programming for
Authority Level 15 functions.
The authority level cannot be changed for
User 0, and no User Access Window can
be assigned. The passcode number for
User 0 can only be changed on the
programmer, or by User 0 from the
command center.
As ENTER PASSCODE message displays
at the command center when User 0 is
entered in response to the User prompt in
the DEL PASSCODE command center
function. Only the Service Authority Level
(User 0) can delete User 0. When a user
other than User 0 tries to delete the
passcode for User 0, the command center
displays NOT IN USE.
User 0 cannot be added from the command
center once it has been deleted. It must be
re-entered using the programmer.
U## Passcode
Default: _ _ _ _ _ _
Selection: Three to six digits ( 0 to 9)
Enter from three to six digits to enable a primary
passcode for this User number.
User ID Code 00 is the Service Authority Level. The
default passcode for the Service Authority Level is
123.
The programmer does not allow you to enter any
passcode number that could conflict with a
secondary (duress) passcode. This rule applies even
if
Duress
is disabled. For example, once a passcode
of 654321 is entered, 654322, 654323, 654320, and
654329 can not be entered.
The D9112 generates a
Usr Code Tamper
report
after six consecutive attempts to enter a passcode
that does not exist in the system. There is no time
limit for the consecutive attempts, but all attempts
must be made from the same command center
address. After a valid passcode is entered, the
counter resets to zero. Entering a passcode with no
authority to execute a function does not count as an
attempt, as long as the passcode is programmed in
the panel.
The D9112 operation depends on the D5200 or
D5300 programmer revision.
In the D5200 revision 1.4 and the D5300 revision
2.15, any passcode entered in the Passcode
Worksheet can turn off bell relays within the scope
of the command center. This is true even if the
passcode has no authority level assigned for any
area.
In the D5200 revision 1.60 and the D5300 revision
2.23 (or higher) , a passcode must be programmed
with an authority level in the area in order to turn
off bell relays for the area. Even if the authority level
does not have the authority to perform any
command center function, if the passcode is assigned
any authority level for the area, it can be used to
turn off bell relays in the area.
U## User Window
Default: Blank
Selection: Blank or 1 to 15
When a User Window is assigned, the user’s
passcode is valid during the time programmed for
the User Window. Program User Window in User
Access Windows.
To enable the user’s passcode all the time, leave this
item blank.
To enable the user’s passcode only during specific
times, enter a User Window number.