D9112B | Program Entry Guide | 3.0 User Interface EN | 49
Bosch Security Systems | 2/04 | 74-06145-000-D
Mstr Arm Inst
Master Arm Instant: [COMMAND] [1] [1]
There are three instant master arming functions enabled by this prompt: Master Arm All Areas Instant, Master
Arm An Area Instant, and Command 11 Local Area Arm Instant.
Normally, these instant master arming functions provide no entry or exit delay, however, if a disable restart is
performed while the area is instant master armed, then an entry delay is provided for the current armed cycle.
Master Arm All Areas (Instant): Arms all areas according to the
Scope
of the command center where the
function is entered (see Cmd Cntr Assignment). No entry or exit delays are provided with this arming function.
Master Arm An Area (Instant): Allows the user to select a single area to arm. No entry or exit delays are
provided with this arming function.
Command 11: Only arms the area where the command center is assigned. No entry or exit delays are provided
with this arming function.
How command center Scope affects area execution:
An Area command center can execute this function only in the area where the command center is
assigned. An Account command center can execute this function in all areas in the account where the
user has authority. A Panel-Wide command center can execute this function in all areas in the panel
where the user has authority.
Default: Blank
Selection: Blank, E, or P
Blank Disable the function panel-wide. Accessing the function using a command, the Command Menu, or
a custom function, displays NO AUTHORITY.
E Enable this function panel-wide. The function can be executed from any area within the command
center’s Scope without entering a passcode.
Programming in O/C Options
Area O/C
and
Restricted O/C
determines whether
Opening
and
Closing
reports can be generated for a particular area.
P Passcode required. When the passcode is entered at the command center, the panel checks the
authority level.
The panel only arms areas where the passcode is authorized and within the
Scope
of the command
center. The command center display shows the areas it is arming.
0101
0101
0101
Force Arming: If a passcode is not required to arm these functions, all authority levels can force arm. To
disable force arming in an area, enter 0 in FA Bypass Max in the Area Parameters section of the program.