D9112B | Program Entry Guide | 5.0 User Access Windows EN | 65
Bosch Security Systems | 2/04 | 74-06145-000-D
To disable the window, both the hours and minutes
spaces must be blank.
0101
0101
0101
Do not program a single window to cross
the midnight boundary. The window stop
time must be later than the window start
time.
5.1 Holiday Indexes for User Access
Windows
You can enable up to four holiday indexes to use
with User Access Windows. Enable at least one
Holiday Index if
UW## Xept Holiday
is
programmed YES for this user window, or if you
want this window active only on specific dates.
Holidays are programmed in the Holiday Indexes
section of the program.
UW## Xept Holiday
Determine if the window is disabled on holidays.
To prevent the window from activating on certain days of the year, use the
Xept Holiday
program item with an
appropriately programmed Holiday Index. When a
Xept Holiday
is programmed YES, the window executes on
the days of the week programmed unless the date is designated as a holiday by the
Holiday Index(es)
selected for use with this window.
Default: No
Selection: Yes or No
Yes Do not activate this window on holidays.
To use this selection, the window must be programmed to activate on at least one day of the week,
and at least one Holiday Index must be used with this window.
No A holiday does not prevent this window from activating.
Use this selection if the User Window is only needed on certain days of the year, or if you want the
User Window to activate regardless of the holiday.
To activate the User Window on certain days of the year, do not program the windows to activate
on any days of the week. Instead, program XEPT Holiday NO and select at least one Holiday Index
with the days of the year you want the window to be active.
UW## Holiday 1
Default: No
Selection: Yes or No
Yes Use Holiday Index 1 with this User
Access Window.
No Do not use Holiday Index 1 with this
User Access Window.
UW## Holiday 2
Default: No
Selection: Yes or No
Yes Use Holiday Index 2 with this User
Access Window.
No Do not use Holiday Index 2 with this
User Access Window.
UW## Holiday 3
Default: No
Selection: Yes or No
Yes Use Holiday Index 3 with this User
Access Window.
No Do not use Holiday Index 3 with this
User Access Window.
UW## Holiday 4
Default: No
Selection: Yes or No
Yes Use Holiday Index 4 with this User
Access Window.
No Do not use Holiday Index 4 with this
User Access Window.