D9112B | Program Entry Guide | 3.0 User Interface EN | 51
Bosch Security Systems | 2/04 | 74-06145-000-D
L## Perim Inst
Perimeter Instant Arm
Default: See Training Sheet
Selection: Blank or E
Blank
Disable this function for Authority Level (L##) specified, if this Command Center Function item
requires a passcode (P).
E
Enable this function for Authority Level specified. When the passcode is entered at the command
center, the panel checks the authority level. The panel executes the function only in areas where the
passcode is authorized.
Programming in O/C Options Perimeter O/C determines whether Perimeter Closing reports can be
generated for a particular area.
Whether Perimeter Closing reports and subsequent Opening reports are generated by this user or
not depends on the L## Perimeter O/C prompt in Authority Lvl Assign.
Perim Delay
Perimeter Delay Arm [COMMAND] [3]:
This command center function arms all perimeter points (see Point Index
Point Type
) in the area where the
command center is assigned. No entry or exit delays are provided with this arming function.
Default: Blank
Selection: Blank, E, or P
Blank Disable the function panel-wide. Accessing the function using a command, the Command Menu, or
a custom function, displays NO AUTHORITY.
E Enable the function panel-wide. The function can be executed without entering a passcode.
Programming in O/C Options
Perimeter O/C
determines whether
Perimeter
Closing
reports can
be generated for a particular area.
P Passcode required. When the passcode is entered at the command center, the panel checks the
authority level. The panel only arms the area if the passcode is authorized.
0101
0101
0101
Force Arming: If a passcode is not required to arm this function, all authority levels can force arm. To
disable force arming in an area, enter 0 in FA Bypass Max in the Area Parameters section of the program.
Page view 50