10.3.8 VMD submenu
Selecting an area for VMD masking
1. From the submenu VMD, select the option “VMD Area.”
The submenu VMD Area appears, and the system displays
the current area selected. Note that the upper left corner
is flashing.
2. Press Select to ‘unlock’ the flashing corner.
3. Use the arrow keys Up, Down, Left, or Right as needed to
move the flashing corner and to set the area for virtual
motion detection.
4. Press Select again to freeze the area and exit the menu.
Note: There is one programmable VMD area. When VMD is
enabled, normal light fluctuations or environmental factors can
contribute to false-positive alarms. Because of this, it is
Saturation -15 to +5 Adjusts the color saturation. -15 gives a
monochrome image.
EXIT Returns to main menu.
Item Selection Description
Item Selection Description
VMD Off, Silent,
OSD
Off - Video Motion Detection (VMD) is off.
Silent - video motion generates silent alarm.
OSD - video motion generates on-screen text
message alarm.
VMD Area Submenu Select to enter the area set-up menu to define the
detection area.
Motion
indicator
Indicates the peak of measured motion in the
selected area. Press either the right, left or center
navigation button to reset.
VMD
sensitivity
Sets the sensitivity for motion to the desired
level. The longer the white bar, the more motion
is required to activate the VMD alarm. Motion
above this level activates alarm.
OSD
alarm text
Alphanumeric Text for on-screen display alarm (16 characters
maximum).
EXIT Returns to main menu.