Solution 64
|
Installer Guide
|
Area Programming
6-4
Bosch Security Systems | 11/05 | BLCC110I
Pulse Count Handover Allowed
This option allows zones from the same area that have both pulse
count and pulse count time programmed the ability to hand over
pulses to other pulse count zones during their respective pulse count
time. Only zones that have an active pulse count time can accept
pulse count handover from another zone.
Burglary delay zones can only handover pulses to other burglary
delay zones. Burglary instant and/or handover zones can handover
pulses to other burglary instant and/or handover zones. 24 hour
non-re zone types can only handover pulses to other 24 hour non
re zones. A 24-hour re zone can only handover pulses to another
24-hour re zone.
Senior Watch
This option requires at least one burglary zone in the corresponding
area to be faulted and restored during the senior watch time. If no
burglary zone has register during the senior watch time, the keypad
will sound an alarm.
To warn the user that senior watch time is about to expire, the keypad
will sound the auto arm pre-alert time (if programmed) prior to
sounding the alarm. See MENU 7-2-6 — Senior Watch Time.
This feature is not applicable when the corresponding area is turned
All On.
An output (Output Event Type 51) can be programmed to operate as
follow Senior Watch if required.
Areas > Properties >
Output Options
MENU 2-1-3
1 Arm/Disarm Speaker Beeps Via RF Keyfob Y
2 Arm/Disarm Speaker Beeps Via Keyswitch Y
3 Siren / Strobe When Part On Allowed Y
4 Alarm On PIN Retry Violations Y
5 Alarm On Exit Error N
6 Alarm On Keyswitch Tamper ( Only If System Armed) Y
7 Reserved N
8 Reserved N
The above options are programmable per area.
Enter [MENU] + [2] + [1] + [3] and select the area from the list
then press [OK].
Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
SPK Beeps Keyfob
SPK Beeps Key/SW
SPK Strobe Part ON
Press  OK ON OFF MENU
Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
Arm/Disarm Speaker Beeps Via RF Key Fob
This option allows audible beeps via the speaker output to verify to
the user that they have successfully turned the area On or O using
the RF keyfob. The speaker output will sound One beep for O, two
beeps for On and three beeps for Part On.
1)
2)
3)
Arm/Disarm Speaker Beeps Via Keyswitch
This option allows audible beeps via the speaker output to verify to
the user that they have successfully turned the area On or O using
a Keyswitch. The speaker output will sound One beep for O, two
beeps for On.
Siren / Strobe When Part On Allowed
This option allows the strobe and audible alarms to operate when the
system is turned Part On or Part 2 On mode.
Alarm On PIN Retry Violations
When the PIN Retry Count as programmed in Menu 1-5-1 is reached
an audible alarm will occur.
Alarm On Exit Error
This option allows you to sound an alarm when an exit error occurs.
An exit error occurs when an entry/exit delay zone becomes unsealled
during exit delay time and remains unsealled at the end of exit delay
time. If this happens, the entry delay will start. If the area is not
turned o (disarmed) before the entry delay time expires an alarm will
occur.
Alarm On Keyswitch Tamper
This option allows you to sound an alarm when a tamper condition
occurs on a zone programmed as a Keyswitch Zone.
Refer to Menu 3-1-1 — Zone Type in Section 8 - Input Programming
for information on programming zones to be a keyswitch input.
Areas > Properties >
Reporting Options
MENU 2-1-4
1 Report PIN Retry Y
2 Report Exit Error Y
3 Smart Lockout N
4 Reserved N
5 Cancel Reports Y
6 Reserved N
7 Open / Close Reports For Part On N
8 Open / Close Reports Only After Alarm N
The above options are programmable per area.
Enter [MENU] + [2] + [1] + [4] and select the area from the list
then press [OK].
Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
Report PIN Retry
Report Exit Error
Smart Lockout
Press  OK ON OFF MENU
Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
Report PIN Retry
When the PIN Retry Count as programmed in Menu 1-5-1 is reached a
Wrong Code Entry alarm report will be sent to the Control Room.
1)
2)
3)