Bosch Solution 64 Specifications Page 58

  • Download
  • Add to my manuals
  • Print
  • Page
    / 108
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 57
Solution 64
|
Installer Guide
|
Output Programming
8-6
Bosch Security Systems | 11/05 | BLCC110I
Outputs > Properties >
Output Polarity
MENU 4-1-3
0 0
The output polarity programs how the output will operate.
Only one option (0 – 15) can be programmed per output. See
the Output Polarity description for more detailled information.
Press [MENU] + [4] + [1] + [3] and use the up and down arrows
to highlight the output in the list and press [OK]. The keypad
will display the current output polarity.
Output Polarity Op001
14 - Speaker Output
Press 0-9 OK to SAVE
Use the up and down arrow keys to select the Output Polarity
required then Press [OK] to save and exit or press [MENU] to
exit without saving.
Option Polarity
0 Normally Open Going Low
1 Normally Open Going Low With Pre Delay
2 Normally Open Latching Low
3 Normally Open Pulsing Low
4 Normally Open One Shot Low
5 Normally Open One Shot Low + Retrigger
6 Normally Open One Shot Low + Reset
7 Normally Low Going Open
8 Normally Low Going Open With Pre Delay
9 Normally Low Latching Open
10 Normally Low Pulsing Open
11 Normally Low One Shot Open
12 Normally Low One Shot Open + Retrigger
13 Normally Low One Shot Open + Reset
14 Horn Speaker (Output 1 or 2 Only)
15 Reserved
Table 18: Output Polarity Types
Normally Open Going Low
Output is normally open circuit and switches to GND when the event
occurs. The output will reset when the output event restores. Time
parameters do not apply to this polarity type.
Normally Open Going Low With Pre Delay
Output is normally open circuit and switches to GND when the event
occurs provided the time parameter has expired. The output will reset
when the output event restores. Time parameters will only set the Pre
Delay when this polarity is selected.
Normally Open Latching Low
Output is normally open circuit and will switch to zero volts when
the event occurs. The output can only be reset manually using the
Output Command Menu.
1)
2)
Normally Open Pulsing Low
Output is normally open circuit and will pulse LOW when the event
occurs. The output will reset when the output event restores. Use the
Time Parameter to set the pulse duration.
Normally Open One Shot Low
Output is normally open circuit and switches to GND when the event
occurs. The output will only reset when the time specied in the Time
Parameter expires. The output will run for the full duration and cannot
be manually reset.
Normally Open One Show Low + Retrigger
Output is normally open circuit and switches to GND when the event
occurs. The output will retrigger each time the event occurs. The
output will reset when the one shot time has expired.
This polarity is ideally suited for security lighting control. A sensor
can be used to trigger an output event and then each time the senso
triggers, the output will operate. The light will turn o when the one
shot timer expires.
Normally Open One Shot Low + Reset
Output is normally open circuit and will switch to GND when the
event occurs. The output will reset when the one shot timer expires or
when the event has restored. This means the operation of the output
can be shortened based on the event and or the programmed time
parameter.
Normally Low Going Open
Output is normally GND and will switch to open circuit when the
event occurs. The output will reset when the output event restores.
Time parameters do not apply to this polarity type.
Normally Low Going Open With Pre Delay
Output is normally GND and will switch to open circuit when the
event occurs provided the time parameter has expired. The output
will reset when the output event restores. Time parameters will only
set the Pre Delay when this polarity is selected.
Normally Low Latching Open
Output is normally GND and will switch to open circuit when the
event occurs. The output can only be reset maually usning the output
Command Menu.
Normally Low Pulsing Open
Output is normally LOW and will pulse OPEN when the event occurs.
The output will reset when the output event restores. Use the Time
Parameter to set the pulse duration.
Normally Low One Shot Open
Output is normally LOW and will switch to open circuit when the
event occurs. The output will only reset when the time specied in
the Time Parameter expires. The output will run for the full duration
and cannot be manually reset.
Normally Low One Show Open + Retrigger
Output is normally LOW and will switch to open circuit when the
event occurs. The output will retrigger each time the event occurs.
The output will reset when the one shot time has expired.
Normally Low One Shot Open + Reset
Output is normally LOW and will switch to open circuit when the
event occurs. The output will reset when the one shot timer expires
or the event has restored. This means the operation of the output
can be shortened based on the event and or the programmed time
parameter.
Page view 57