PRE-INSTALLATION
6 720 644 743b (2011/08)
21
3.8 FLUE OPTIONS
FLUE LENGTHS
The flue systems have different maximum flue lengths
The Greenstar series has the option of two horizontal
60/100 RSF (telescopic and longer telescopic) and one
horizontal 80/125 RSF (telescopic) flue system and two
vertical RSF (60/100 or 80/125) flue systems:
The next page shows various fluing options.
Refer to the Flue options in table 21 for the straight flue
lengths required to achieve the maximum flue length.
CAUTION: Non accessible flue systems:
B Where a flue system is not going to be
accessible, provision must be made for
service and inspection.
B Voids containing concealed flues must
have at least one inspection hatch no less
than 300mm square.
B Flue joints within the void must not be
more than 1.5 metres from the edge of
the inspection hatch.
B Inspection hatches should be located at
changes of direction.
B If this is not possible, bends should be
viewable from both directions.
NOTICE: Effective flue lengths:
B each 90° bend used is equivalent to
2 metres of straight flue
B each 45° bend used is equivalent to
1 metre of straight flue
Plume management kits are available for the
60/100 horizontal flue system.
Refer to the manual supplied with the plume
management kits for complete installation
instructions
i System boilers
Maximum total
flue length (mm)
FLUE TYPE 60/100 80/125
1 Telescopic horizontal flue assembly 570 1,070
Longer telescopic horizontal flue assembly 790 N/A
2 Horizontal flue extension 4,600 13,000
3 Horizontal flue with 1 x 90° bend 2,600 11,000
4 Horizontal flue with 2 x 90° bends N/A 9,000
5 High level horizontal flue 4,600 13,000
6 High level horizontal flue with 2 x 90° bends 2,600 11,000
7 High level horizontal flue with 3 x 90° bends N/A 9,000
8 Vertical balanced flue assembly 6,400 15,000
9 Vertical balanced flue with 2 x 90° bends 2,400 11,000
10 Vertical balanced flue with 2 x 45° bends 4,400 13,000
Tab. 21 Flue options
Part number Flue Description
7 716 191 082 60/100 Telescopic horizontal flue
assembly
7 716 191 171 60/100 Longer telescopic
horizontal flue assembly
7 719 003 702 80/125 Telescopic horizontal flue
assembly
7 719 002 430 60/100 Vertical flue assembly
7 719 002 431 80/125 Vertical flue assembly
Tab. 22 Flue option part numbers