8-1
Bosch Security Systems 10/12 BLCC600BI
SECTION 8
Output Programming
T
he Solution 144 is capable of controlling up to 16
outputs. The first 4 outputs are on the main control
board and an additional 4 outputs are provided using an
output expander module. Each output can have its own
unique name up to 16 characters to identify it on the
system for display and reporting purposes.
Under the commands menu you are able to view the
status of any output and to change its on/off condition. In
the case of latching output types, you will be required to
reset the output manually using these commands.
Outputs are programmed using an event type. First select
the event type that will cause the output to trigger. Then
select the polarity of the event, if it is low and goes high or
high and goes low. If the event is pulsing or one shot type,
the time parameter must also be programmed to define
the time of the pulse.
Event Assignment, this is extremely important parameter
and has a different meaning depending on the event type
selected. For example, event type “24 - Area Part On” the
event assignment selects the Area that is armed in part on
for the output to trigger. If you set the event assignment
to 1, then it will correspond to area 1 and so on, setting
it to zero means all areas. See the event type table for
more detail on the relationship of event type to event
assignment.
Outputs 1 and 2 are special outputs that can be configured
as horn speaker polarity types and are monitored to
report a device connection trouble. Output 4 is a dry
relay contact which has a optional jumper that allows you
to switch positive or negative without the need to add
additional wiring.
The outputs are all protected and will shut down
individually under overload conditions. A report will be
generated and a displayed on the keypad to indicate the
trouble condition.
OUTPUT COMMANDS
Outputs > Commands >
Output Status
-
-
-
MENU 4-0-0
This command allows you to view the current status of
any system output.
1) Press [MENU] + [4] + [0] + [0] and select the output
you want to view from the list then press [OK].
Alternatively, you can directly enter the output
number that you want to view then press [OK].
The keypad will display the following when the output
is currently in the OFF state and ready to activate.
External Siren Op1
Is OFF and Ready
Press OK or MENU
The keypad will display the following when the output
is currently in the OFF state but the connection is
missing.
External Siren Op1
Is OFF and Ready
Connection Trouble
Press OK or MENU
The keypad will display the following when the output
is currently in the ON state and ready.
External Siren Op1
Is ON and TIMING
Triggered
Press OK or MENU
The keypad will display the following when the
output is currently in the ON state but the connection
is missing.
External Siren Op1
Is ON and TIMING
Connection Trouble
Press OK or MENU
2) Press [OK] or [MENU] to exit.