Solution-144
Installation Manual Output Programming
8-4
Bosch Security Systems 10/12 BLCC600BI
OUTPUT PROPERTIES
Outputs > Properties >
Output Name
-
MENU 4-1-0
O u t p u t 1 N a m e
This menu allows you to program the name for each
output. Output names can be up to 16 characters long.
1) Press [MENU] + [4] + [1] + [0] and use the up and
down arrows to highlight the Output in the list
then press [OK]. Alternatively, you can enter the
output number directly and press [OK].
2) Use the arrow and number keys to move and
change text. When the Output Name is complete,
press [OK]. At any time you can press the [OFF] key
to clear the text from the current cursor position to
the end of the line. .
Output Name Op1
External Siren
Press  OK to SAVE
See Alpha Text Programming in Section 4 —
Programming Overview for further detail on entering
alpha text.
Outputs > Properties >
Event Type
MENU 4-1-1
0 0 0
This menu allows you to set the output event type. See the
Output Event Type Table and Event Type Descriptions in
this section for more information on the available options.
1) Press [MENU] + [4] + [1] + [1] and use the up and
down arrows to highlight the Output in the list
then press [OK]. Alternatively, you can directly
enter the output number and press [OK].
2) Use the up and down arrow keys to select the Event
Type required then press [OK] to save and exit or
press [MENU] to exit without saving. It is also
possible to directly enter the Event Type number
then press [OK].
Event Type Op1
36 - External Audible
Press  0-9 OK to Save
01 - Battery Trouble
This event type will cause the output to operate when
the panel detects a low or missing stand-by battery
and will reset once a successful battery test has been
performed.
Battery tests are performed automatically every 4 hours
and when the system is armed. A manual test can also be
requested at any time while the system is disarmed. See
MENU 7-9-1 — Battery Test
02 – AC Trouble
This event type will cause the output to operate when
the panel detects that the AC mains power has been
missing for 1 minute and will reset when the power has
been restored for 1 minute.
03 – Telco Line Fail
This event type will cause the output to operate
when the panel detects that the telco line has been
disconnected for 30 seconds and will reset when the line
has been restored.
04 – Comm Fail
This event type will cause the output to operate if the
panel fails to report to destination1 or 2 or both. The
panel will try to send the report as many times as set in
the call attempt counter before registering a comm fail.
The output will restore as soon as a successful report has
been sent to the destination that has previously failed to
report. If both Destination 1 and Destination 2 had failed
to report then successful report to both destinations will
need to be made before the output will reset. See MENU
5-2-0 — Call Attempt Count
05 – 3rd Dial Attempt
This event type will cause the output to operate when
the panel has made 3 unsuccessful call attempts to the
base station. The output will reset when all pending
messages have been sent or when the maximum number
of call attempts have been made.
06 – Dest Reporting
This event type will cause the output to operate when
the panel is communicating via Destination 1 or 2 and
will reset when the transmission ends.
07 – Reserved
08 – Dest Kiss Off
This event type will cause the output to operate when
the panel receives an kiss-off acknowledgment from the
receiving party while communicating via destination 1
or 2. It is recommended that this output is programmed
with a one-shot timer.
09 – User Keyfob Func 1
This event type will cause the output to operate when
Key X is pressed on the Keyfob. This output type is user
specific and requires a 4 button keyfob.