6000 Series Programmer's Guide
Error Messages
If an illegal programming condition is discovered while programming or executing programs, the 6000 controller responds
with an error message. If a program execution error is detected, the program is aborted.
The table below lists all the error messages that relate to Following, and indicates the command and cause that may generate
them. These error messages are displayed only if the error level is set to level 4 with the ERRLVL4 command (this is the
default setting).
Error Message Cause
FOLMAS NOT SPECIFIED No FOLMAS for the axis is currently specified. It will occur if FMCNEW, FSHFC, or FSHFD
commands are executed and no FOLMAS command was executed, or FOLMASØ was
executed.
INCORRECT DATA Velocity (V), acceleration (A), or deceleration (AD) command is zero. (used by FSHFC
& FSHFD)
INVALID CONDITIONS FOR
COMMAND
The FOLMD command value is too small to achieve the preset distance and still
remain within the FOLRN/FOLRD ratio.
A command phase shift cannot be performed:
FSHFD.............. Error if already shifting or performing other time based move.
FSHFC.............. Error if currently executing a FSHFD move, or if currently executing another
FSHFC move in the opposite direction.
The FOLEN1 command was given while a profile was suspended by a GOWHEN.
INVALID DATA The parameter supplied with the command is invalid.
FFILT.............. Error if: smooth number is not 0-4
FMCLEN............ Error if: master steps > 999999999 or negative
FMCP................. Error if: master steps > 999999999 or <-999999999
FOLMD.............. Error if: master steps > 999999999 or negative
FOLRD.............. Error if: master steps > 999999999 or negative
FOLRN.............. Error if: slave steps>999999999 or negative
FSHFC.............. Error if: number is not 0-3
FSHFD.............. Error if: slave steps>999999999 or <-999999999
GOWHEN............ Error if: position > 999999999 or <-999999999
WAIT................. Error if: position > 999999999 or <-999999999
Error if a GO command is given in the preset positioning mode (MCØ) and:
FOLRN = zero
FOLMD = zero, or too small (see
Preset Moves
section on page 200)
INVALID FOLMAS SPECIFIED An illegal master was specified in FOLMAS. A slave may never use its own
commanded position or feedback source as its master.
INVALID RATIO Error if the FOLRN:FOLRD ratio after scaling is > 127 when a GO is executed.
MOTION IN PROGRESS The FOLEN1 command was given while that slave was moving in a non-Following
mode.
NOT VALID DURING FOLLOWING
MOTION
A GO command was given while moving in the Following mode (FOLEN1) and while in
the preset positioning mode (MCØ).
NOT VALID DURING RAMP A GO command was given while moving in a Following ramp and while in the
continuous positioning mode (MC1). Following status (FS) bit #3 will be set to 1.