5. Overview of Parameters
Fkt-TabelleA06
Additions list !
Function
Value in parameter LOAD LIM ( PQRS 19 )
means torque in % of peak torque
Type code field "speed command value " = D
floating decimal point of the speed
command value
Type code field " speed command
value " = A and " add. interface " = D
Analogue speed comm. value
in parameter record P, Q
Binary speed command value
in parameter record R, S
Type code field "2nd enc. input " = P
2nd encoder input is used as
motor feedback of motor 2
Slave mode:
voltage at analogue input E1/E2 at
terminal strip X4 is interpreted
as torque command value
Spindle positioning with speed POS RPM
( PQRS 19 ), rotational direction as per
qualifying sign of the presently applied
speed command value
with control input EXT POS = 1,
control input E-STOP = 1 0
and power failure:
command value ramp or smoothing active!
with RAC 3 only:
compensation of mains undervoltage active
with control input EXT POS = 1:
at analogue input N equals
10V = speed P-MAXRPM ( PQRS15 )
with RAC 2.2 only:
bleeder monitoring active
switching analogue input M:
output of the approximate drive torque
and switching of analogue output N:
torque command value is output
< 1 >
< 2 >
< 4 >
< 8 >
< 16 >
< 32 >
< 64 >
< 128 >
< 256 >
< 512 >
< 0 >
< 0 >
< 0 >
< 0 >
< 0 >
< 0 >
< 0 >
< 0 >
< 0 >
< 0 >
Relevant summand
3.10
3.2.2
3.16
3.17
3.6.1
3.5
3.4
3.2
3.19
3.10.1
See section
Function
value in parameter LOAD LIM( PQRS 19 )
means power in kW
Type code field " speed command value" = D
binary coded speed command value
Type code field " 2nd enc. input " = P
2nd encoder input is input for
spindle feedback
analogue input E1/E2 at terminal strip
X4 supports speed default
spindle positioning with speed POS RPM
( PQRS 19 ), using shortest path
with control input EXT POS = 1
control input E-STOP 1 0
and mains failure:
command value ramp or smoothing inactive!
with RAC 3 only:
compensation of mains undervoltage inactive
10V = speed MAXRPM ( A01 )
with RAC 2.2 only:
bleeder monitoring not
operating
no switching of analogue outputs
M and N via function parameter ( A06 )
Figure 100: Function table for parameter FUNCT2 (A06)