3. Controller Functions
3.2.2 Digital Speed Command Value (option)
The "digital speed command value" enables a task to be matched to the
specific plant requirements.
The speed command value can be transferred directly from the PLC
controller, binary or floating-point coded, depending on the required
speed resolution. The parallel signals are interrogated by the control unit
every 1.2 ms.
In plants with severe interference, and in the case of long lines, digital
parallel transmission ensures high speed command value accuracy.
Speed command value resolution:
binary coded 1 rpm
floating-command coded to 0.0005 rpm
The control unit must be fitted with the digital command value interface
(type code field "speed command value = D").
The maximum speed of the motor MAX RPM is not exceeded, even with
excessively high speed command values!
Function conversion
Speed limits
Figure 20: Parameters for a digital speed command value
Designation
FUNCT 2
MAXRPM
FUNCT 1
Function
dig. speed comm. value, binary coded
dig. speed comm. value, floating comma coded
maximum speed of the motor
weighting change of the digital speed command
value with respect to parameter value of A 01:
Value range or value
< 0 >
< 2 >
1....24000
< 1024 >
Parameter
A 06
A 01
A 05
PARAMETER PROTOCOL !
( 1/min )
Para-Sollwert-Digital
A 01
N
comm
A 01
= • N
comm
digital
16383
Page view 40