1. Commissioning INDRAMAT AC Main Spindle Drives
Operating the drive with the
command value box
1.4.5 Initial Start-Up
Switch on the controller enabling signal on the command value box.
Apply a small command value. The speed of the drive must follow the
command value input.
In the event of a fault, the drive can "chatter" uncontrollably.
Disconnect the controller enabling signal immediately. If the
motor rotates in an uncoordinated way, check that the phasing
of the motor power connections is correct. If the motor rotates
at low speeds only, without following the command value, then
check the feedback connections!
The drive must reach the speed specified in parameter MAX RPM (A01)
when the command value voltage programmed in parameter CMD VOLT
(A02) is applied.
Checking the speed/
command value ratio