Solution 64
|
Installer Guide
|
Input Programming
Bosch Security Systems | 11/05 | BLCC110I
7-3
Press [ON] to arm the zone in Part 2 mode or press [OK] to exit.
Front Door Zn001
Is not armed in PART2
To Enable, Press ON,
To Go Back Press OK
Press [OFF] to disarm the zone in Part 2 mode or press [OK] to
exit.
Main Bedroom Zn002
Is a armed in PART2
To remove, Press OFF
To Go Back Press OK
4)
5)
Zone Default Table
The table below lists the default values for all zone parameters in the Solution 64. By default, zones 5 to 16 are set as Instant zones
and zones 17 to 64 are set as Not Used. Zones marked as Not Used do not require EOL resistors to be tted.
Programming Option Zone 1 Zone 2 Zone 3 Zone 4 Zones 5 to 16 Zones 17 to 64
Zone Name Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 - Zone 16 Zone 17 - Zone 64
Zone Type 1 = Delay 1 5 = Handover 5 = Handover 5 = Handover 3 = Instant 0 = Not Used
Area Assignment 1 1 1 1 1 1
Pulse Count 0 0 0 0 0 0
Pulse Count Time (Sec’s) 120 120 120 120 120 120
Access Group 0 0 0 0 0 0
Report Route 2 2 2 2 2 2
Reporting Options
Lockout Dialler Y Y Y Y Y Y
Report Alarm Y Y Y Y Y Y
Report Alarm Restore Y Y Y Y Y Y
Report Trouble Y Y Y Y Y Y
Report Trouble Restore Y Y Y Y Y Y
Report Bypass Y Y Y Y Y Y
Report Bypass Restore Y Y Y Y Y Y
Delay Report N N N N N N
Zone Options
Lockout Siren Y Y Y Y Y Y
Silent Alarm N N N N N N
Inverted Seal N N N N N N
Bypass Allowed Y Y Y Y Y Y
Sensor Watch N N N N N N
Armed When Part On Y Y Y Y Y Y
Reserved N N N N N N
Test On Exit N Y Y Y Y Y
Table 16: Zone Defaults
Inputs > Commands >
Set Part 2 Zones
-
MENU 3-0-4
This menu allows you to program which zones are to be
exluded or bypassed when an area has been turned On in Part
Mode 2.
Enter [MENU] + [3] + [0] + [4] and use the up and down arrows
to highlight the area from the list then press [OK].
Use the up and down arrow keys to select the zone(s) that you
want to disable in Part 2, then press [OK]. Alternatively, you
can enter the zone number directly then press [OK]. Zones
marked with a tick are active and will alarm in Part 2 mode.
Zn001 Front Door
Zn002 Main Bedroom
Zn003 Lounge Window
Press  OK or MENU
One of the following messages will be displayed depending on
the current zone programming.
1)
2)
3)