Bosch Solution 64 Specifications Page 48

  • Download
  • Add to my manuals
  • Print
  • Page
    / 108
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 47
Solution 64
|
Installer Guide
|
Input Programming
7-8
Bosch Security Systems | 11/05 | BLCC110I
Inputs > Zone Properties >
Zone Options
MENU 3-1-8
1 Lockout Siren Y
2 Silent Alarm N
3 Inverted Seal N
4 Bypass Allowed Y
5 Sensor Watch N
6 Armed When in Part Mode 1 Y
7 Reserved N
8 Test On Exit Y
The above options are programmable per zone.
Press [MENU] + [3] + [1] + [8] and use the up and down arrows
to highlight the Zone in the list then press [OK]. Alternatively,
you can enter the zone number directly and press [OK]. The
keypad will display the Report Options for the currently
selected zone.
Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
Lockout Siren
Silent Alarm
Inverted Seal
Press  OK ON OFF MENU
Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
Lockout Siren
Setting this option will enable Siren Lockout functionality for the
respective zone(s). All zones in the system can be individually
programmed for Siren Lockout.
When enabled the respective zone will be allowed to cause the
sirens to sound each time a new alarm is triggered provided that the
Swinger Siren count has not been reached. If the zone is triggered and
the Swinger Siren count has been reached then the siren will become
locked out for that zone and no further siren activations will occur
from that zone. Only zones which have been locked out are prevented
frrom triggering the sirens.
Siren lockout will be reset on the next arming cycle.
See MENU 7-4-3 — Swinger Siren to set the shutdown count.
Silent Alarm
Setting this option will set the correspondiing zone to become a silent
zone. Audible alarm outputs will not sound when a silent zone is
triggered.
Inverted Seal
Setting this option allows a normally-open sensor or device to operate
as a normally-closed device by reversing the open/closed state of the
zone loop. (eg. When the zone loop is open, the system will register
the zone loop as closed or normal.)
Bypass Allowed
Setting this option allows users with the appropriate access level to
manually bypass this zone eectively removing it from the area for
the current arming cycle. All zone types including 24hour zones can
be bypassed if this option is selected. Bypassed zones will be reset
when the area is turned o or disarmed.
1)
2)
3)
Sensor Watch
Setting this option causes the system to monitor the zones activity
while the corresponding area is in the disarmed state. If the zone
fails to unseal and reseal at least once during the Sensor Watch
Time period a system trouble will be displayed on the keypad and a
Sensor Watch report for the corresponding zone will be sent to the
programmed destination. See MENU 3-9-2 — Sensor Watch to set the
time period.
i
Note
Sensor Watch monitoring is only active when the area is in the
disarmed state. 24 hour zone types cannot be monitored using
the Sensor Watch feature.
Armed When In Part Mode 1
Setting this option causes the zone to be active or monitored when
the corresponding area is armed in Part On Mode 1.
If this option is not set, the corresponding zone will be inactive when
the area is armed in Part Mode 1 allowing users to move freely within
this zone and not trigger an alarm.
Test On Exit
Setting this option will cause the system to prompt the user that a
zone or zones are not sealled when they attempt to arm the area in
which the zone belongs. An error beep will sound and a zone trouble
message will display on the keypad advising the user to seal the
zone(s) or to bypass them before the area will arm.
If this option is disabled the zone will not be tested during the arming
sequence and the system will arm. If the zone(s) are unsealled at the
end of exit time a Zone Trouble report will be sent.
Page view 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 107 108

Comments to this Manuals

No comments