Page view 53
Solution 64
|
Installer Guide
|
Output Programming
8-2
Bosch Security Systems | 11/05 | BLCC110I
Output 1 Name Op001
Output Is Off
To Turn ON, Press ON
To Go Back Press OK
The keypad will display the following when the output is on. To
turn the output O, press [OFF].
Output 1 Name Op001
Output Is ON
To Turn OFF, Press OFF
To Go Back Press OK
Press [OK] or [MENU] when nished.
Output Properties
Outputs > Properties >
Output Name
-
MENU 4-1-0
O u t p u t 1 N a m e
This menu allows you to program the name for each output.
Output names can be up to 16 characters long.
Enter [MENU] + [4] + [1] + [0] and use the up and down arrows
to highlight the Output in the list then press [OK].
Alternatively, you can enter the output number directly and
press [OK].
Use the arrow and number keys to move and change text.
When the Output Name is complete, press [OK]. At any time
you can press the [OFF] key to clear the text from the current
cursor position to the end of the line.
Output Name Op001
Output 1
Press  OK to SAVE
i
Note
See Alpha Text Programming in Section 4 — Programming
Overview for further detail on entering alpha text.
Outputs > Properties >
Event Type
MENU 4-1-1
0 0 0
This menu allows you to set the output even type. See the
Output Event Type Table and Event Type Descriptions in this
section for more information on the available options.
Press [MENU] + [4] + [1] + [1] and use the up and down arrows
to highlight the Output in the list then press [OK].
Alternatively, you can directly enter the output number and
press [OK].
Use the up and down arrow keys to select the Event Type
required then Press [OK] to save and exit or press [MENU] to
exit without saving. It is also possible to directly enter the
Event Type number then Press [OK].
3)
4)
1)
2)
1)
2)
Event Type Op001
36 - External Audible
Press 0-9 OK to SAVE
1 - Battery Trouble
This event type will cause the output to operate when the panel
detects a low or missing stand-by battery and will reset once a
successful battery test has been performed.
Battery tests are performed automatically every 4 hours and when
the system is armed. A manual test can also be requested at any time
while the system is disarmed. See MENU 7-9-1 — Battery Test
2 AC Trouble
This event type will cause the output to operate when the panel
detects that the AC mains power has been missing for 1 minute and
will reset when the power has been restored for 1 minute.
3 Telephone Line Trouble
This event type will cause the output to operate when the panel
detects that the telco line has been disconnected for 30 seconds and
will reset when the line has been restored.
4 Comm Fail Destination 1 / 2
This event type will cause the output to operate if the panel fails to
report a signal to report destination1 or 2 or both. The panel will try
to send the report as many times as set in the call attempt counter
before registering a comm fail.
The output will restore as soon as a successful report has been
sent to the destination that has previously failed to report. If both
Destination 1 and Destination 2 had failed to report then successful
report to both destinations will need to be made before the output
will reset. See MENU 5-2-0 — Call Attempt Count
5 Third Failed Dialler Attempt
This event type will cause the output to operate when the panel has
made 3 unsuccessful call attempts to the base station. The output
will reset when all pending messages have been sent or when the
maximum number of call attempts have been made.
6 Destination 1 Reporting
This event type will cause the output to operate when the panel is
communicating to Destination 1 and will reset when the transmission
ends.
7 Destination 2 Reporting
This event type will cause the output to operate when the panel is
communicating to Destination 2 and will reset when the transmission
ends.
8 Destination 1/2 Kiss-Off
This event type will cause the output to operate when the panel
receives an kiss-o acknowledgment from the receiving party while
communication to destination 1 or 2. It is recommended that this
output is programmed with a one-shot timer.
9 Destination 1 Kiss-Off
This event type will cause the output to operate when the panel
receives a kiss-o acknowledgment from the receiving party while
communicating to destination 1. It is recommended that this output
is programmed with a one-shot timer.