Solution 64
|
Installer Guide
|
Output Programming
Bosch Security Systems | 11/05 | BLCC110I
8-3
10 Destination 2 Kiss-Off
This event type will cause the output to operate when the panel
receives a kiss-o acknowledgment from the receiving party while
communicating to destination 2. It is recommended that this output
is programmed with a one-shot timer.
11 Dialler Disabled
This event type will cause the output to operate if the panel reporting
functions are manually disabled and will reset when reporting is
enabled. See MENU 5-2-1 — Dialer Options.
12 Horn Speaker Missing
This event type will cause the output to operate when the panel
detects that a horn speaker is missing. The output will reset when
the horn speaker is reconnected. Only output 1 and 2 can be
programmed as a horn speaker outputs. See MENU 4-1-3 — Output
Polarity for information on conguring an output to drive a horn
speaker
13 Output Trouble
This event type will cause the output to operate when the panel
detects that an output device is missing or in an overload condition.
The output will reset when all failed outputs have restored or the
overload condition has been removed.
14 Panel On-Line
This event type will cause the output to operate when the panel
seizes the phone line and will reset when the phone line is released.
15 Incoming Call
This event type will cause the output to operate when the panel
detects an incoming call on the phone line and will reset when the
ring signal stops.
16 System Trouble
This event type will cause the output to operate when the panel
detects a system trouble condition and will reset when the condition
is cleared.
17 Box Tamper
This event type will cause the output to operate when the panel
detects that the onboard enclosure tamper circuit is open. The output
will reset when the tamper circuit is closed. No EOL resistor is required
on this input.
18 Zone Trouble
This event type will cause the output to operate when the panel
detects that a zone has a trouble condition and will reset when the
trouble condition has cleared.
19 Zone Mirror
This event type will cause the output to operate when a specic zone
is open or unsealled and will reset when the zone closes.
See MENU 4-1-2 — Event Assignment for infomation on how to set
the zone to mirror.
20 Zone Alarm
This event type will cause the output to operate when a specic zone
has triggered an alarm and will reset when the corresponding area is
disarmed. For a non 24hour zone to trigger an alarm the area must be
armed. See MENU 4-1-2 — Event Assignment for infomation on how
to set the zone to monitor.
21 Area Disarmed
This event type will cause the output to operate as soon as the
corresponding area is disarmed and will reset when the area is armed
in either the All On or Part On modes.
If the output event assignment for this output is set to zero (all areas),
then all areas must be disarmed for the output to operate. The output
will reset as soon as any area is armed in either the All On or Part On
modes.
22 Area Armed (Any)
This event type will cause the output to operate when the selected
area is armed in either All On or Part On mode. The output will reset
when the area is disarmed.
If the event assignment for this output has been set to zero (all areas)
then the output will only operate when all areas have been armed
in All On or Part On mode. The output will reset as soon any area is
disarmed.
23 Area All On
This event type will cause the output to operate as soon as a specic
area is armed All On mode and will reset when the area is disarmed.
If the event assignment for this output has been set to zero (all areas),
then the output will only operate when all areas have been armed in
the All On mode and will reset as soon as any area is disarmed.
24 Area Part On
This event type will cause the output to operate as soon as a specic
area is armed Part On mode and will reset when the area is disarmed.
If the event assignment for this output has been set to zero (all areas),
then the output will only operate when all areas have been armed in
the Part On mode and will reset as soon as any area is disarmed.
25 Area Part 2 On
This event type will cause the output to operate as soon as a
specic area is armed Part 2 On mode and will reset when the ares is
disarmed.
If the event assignment for this output has been set to zero (all areas),
then the output will only operate when all areas have been armed in
the Part 2 On mode and will reset as soon as any area is disarmed.
26 Entry Time
This event type will cause the output to operate while either Entry
Timer 1, Entry Timer 2 or the Part Mode Entry Timer is active. The
output will reset when the entry timer expires or the corresponding
area is disarmed.
27 Exit Time
This event type will cause the output to operate while Exit Timer
is active. The output will reset when the exit timer expires or the
corresponding area is disarmed.
28 End Of Exit Time
This event type will cause the output to operate when the Exit Time
expires and will reset when the corresponding area is disarmed.
29 Chime On
This event type will cause the output to operate when Chime Mode is
activated and will reset when Chime Mode is turned o.
If the event assignment for this output is set to zero (all areas), then
the output will operate as soon as Chime Mode is activated in any
area and will reset when Chime Mode is turned o in all areas.