KEY TO SYMBOLS AND SAFETY PRECAUTIONS
6 720 644 743b (2011/08)
5
British Standards:
Where no specific instruction is given, reference should
be made to the relevant British Standard codes of
Practice.
BS7074:1 Code of practice for domestic and hot water
supply
BS6891 Installation of low pressure gas pipe work up
to 28mm (R1)
BS5546 Installation of gas hot water supplies for
domestic purposes
EN12828 Central heating for domestic premises
BS5440:1 Flues and ventilation for gas appliances of
rated heating not exceeding 70kW (net) :
Flues
BS5440:2 Flues and ventilation for gas appliances of
rated heating not exceeding 70kW (net) : Air
Supply
BS7593 Treatment of water in domestic hot water
central heating systems
BS6798 Installation of gas fired boilers of rated input
up to 70kW (net)
Irish Standards
The relevant Irish standards should be followed,
including:
• ECTI National rules for electrical installations
• IS 813:2002 for Domestic Gas Installations.
LPG Installations
An appliance using L.P.G. must not be installed in a room
or internal space below ground level unless one side of
the building is open to the ground.
Timber framed building:
Where the boiler is to be fitted to a timber framed
building the guidelines laid down in BS5440: Part 1 and
IGE "Gas Installations in Timber Frame Buildings” should
be adhered to.
Potable water:
All seals, joints and compounds (including flux and
solder) and components used as part of the secondary
domestic water system must be approved by WRAS.
CH Water:
Artificially softened water must not be used to fill the
central heating system.
BOILER FEATURES AND CHECKLIST
• Pre-wired and pre-plumbed
• Galvanised steel inner frame
• Digital control system
• FX Intelligent controls
• Low NOx option
• Automatic ignition
• Direct burner ignition electrodes
• Built-in frost protection
• Built-in fault finding diagnostics
• Modulating automatic gas valve
• Combustion air fan with speed regulator
• CH temperature sensor & control
• Pump anti-seizure protection
• Flue gas temperature sensor
• Condensate syphonic trap
• Temperature control
CHECK LIST
- HARDWARE LITERATURE PACK:
Qty.
Greenstar 12i/15i/18i & 24i System
Installation, Commissioning and Servicing
Instructions
1
Users Instructions 1
Consumer Guarantee Card 1
Sealing Pack: 1
- Compression Nut 22mm 3
- Compression Ring 22mm 3
- Compression Nut 15mm 3
- Compression Ring 15mm 3
- Fibre Washer 18.6 x 13.5 x 1.5 2
- Fibre Washer 23.9 x 17.2 x 1.5 2
- Bonded Washer 3/4“ for gas 1
Syphon assembly 1
- Installation instructions 1
Warranty Return Envelope 1
Tab. 4 Hardware lit pack - checklist